SDS
SAFETY DATA SHEET
PREMIER BUILDING SOLUTIONS, INC.
Page 12 of 21
Version: 1.2
Revision Date: 12/5/2016
XTRABOND 250 100% RTV SILICONE SEALANT
12
Method: OECD Test Guideline 474
Result: negative
Remarks: Based on data from similar materials
Carbon black:
Genotoxicity in vitro:
Test Type: Bacterial reverse mutation assay (AMES)
Result: negative
Carcinogenicity
Not classified based on available information.
Ingredients:
Titanium dioxide:
Species: Rat
Application Route: inhalation (dust/mist/fume)
Exposure time: 24 Months
Method: OECD Test Guideline 453
Result: positive
Remarks: The mechanism or mode of action may not be relevant in humans. The substance is inextricably
bound in the product and therefore does not contribute to a dust inhalation hazard.
Carcinogenicity - Assessment:
Limited evidence of carcinogenicity in inhalation studies with animals.
Aluminum:
Species: Rat
Application Route: inhalation (dust/mist/fume)
Exposure time: 86 weeks
Result: negative
IARC: Group 2B: Possibly carcinogenic to humans
(Titanium dioxide CAS# 13463-67-7)
(Carbon Black CAS# 1333-86-4)
OSHA: No ingredient of this product present at levels greater than or equal to 0.1% is identified as a
carcinogen or potential carcinogen by OSHA.
NTP: No ingredient of this product present at levels greater than or equal to 0.1% is identified as a known or
anticipated carcinogen by NTP.
Reproductive toxicity
Not classified based on available information.