Instructions

Intended Use
With the outdoor radio motion detector an appropriate wireless
remote-control switch of the RSL system (or a load attached to it) can
be switched on or off wirelessly.
The motion detector responds to temperature changes within the
detection range, e.g. if a person, an animal or a car enters the
detection area.
Because of this, the motion detector is used for monitoring of
entrances, stairs etc.
For safety and approval purposes, you must not rebuild and/or modify
this product. If you use the product for purposes other than those
described above, the product may be damaged. In addition, improper
use can result in short circuits, res, electric shocks or other hazards.
Read the instructions carefully and store them in a safe place. Make
this product available to third parties only together with its operating
instructions.
This product complies with the statutory national and European
requirements. All company names and product names are trademarks
of their respective owners. All rights reserved.
Safety Instructions
Read the operating instructions carefully and
especially observe the safety information. If you do not
follow the safety instructions and information on
proper handling in this manual, we assume no liability
for any resulting personal injury or damage to property.
Such cases will invalidate the warranty/guarantee.
a) General Information
The device is not a toy. Keep it out of the reach of children and pets.
Do not leave packaging material lying around carelessly. This may
become dangerous playing material for children.
Protect the product from extreme temperatures, direct sunlight,
strong jolts, high humidity, moisture, ammable gases, steam and
solvents.
Do not place the product under any mechanical stress.
If it is no longer possible to operate the product safely, take it out of
operation and protect it from any accidental use. Safe operation can
no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
Please handle the product carefully. Jolts, impacts or a fall even
from a low height can damage the product.
Do not use this product in hospitals or medical institutions. Although
the transmitter in the radio remote control emits only relatively weak
radio signals, these may lead to malfunction of life-support systems.
The same may be the case in other areas.
The product may be installed and used outdoors and indoors.
Do not use this product in rooms or under adverse ambient
conditions where combustible gases, vapours or dust are or may be
present! There is a risk of explosion!
The product must not be exposed to extreme temperatures, strong
vibrations or heavy mechanical stress.
In commercial institutions, the accident prevention regulations of
the employer’s liability insurance association for electrical systems
and operating facilities are to be observed!
Consult an expert when in doubt about operation, safety or
connection of the product.
Maintenance, modications and repairs must only be completed by
a technician or an authorised repair centre.
If you have questions which remain unanswered by these operating
instructions, contact our technical support service or other technical
personnel.
b) Connected devices
Also observe the safety and operating instructions of any other
devices which are connected to the product.
c) Batteries
Correct polarity must be observed while inserting the battery.
The batteries should be removed from the device if it is not used
for a long period of time to avoid damage through leaking. Leaking
or damaged batteries might cause acid burns when in contact with
skin, therefore use suitable protective gloves to handle corrupted
batteries.
Batteries must be kept out of reach of children. Do not leave batteries
lying around, as there is risk, that children or pets swallow them.
Up-to-date Operating Instructions
Download the latest operating instructions at
www.conrad.com/downloads or scan the QR code
shown. Follow the instructions on the website.
Explanation of Symbols
The symbol with the lightning in the triangle is used if
there is a risk to your health, e.g. due to an electric shock.
The symbol with the exclamation mark in the triangle is
used to indicate important information in these operating
instructions. Always read this information carefully.
The arrow symbol indicates special information and
advice on operation.
This product must only be used in dry, enclosed indoor
areas. It must not become damp or wet, as this may result
in a fatal electric shock!
Delivery Content
Outdoor radio motion detector with wall bracket
Operating Instructions
Operating instructions
Outdoor radio motion detector “RSL”
Item no. 1761750
All batteries should be replaced at the same time. Mixing old and
new batteries in the device can lead to battery leakage and device
damage.
Batteries must not be dismantled, short-circuited or thrown into
re. Never recharge nonrechargeable batteries. There is a risk of
explosion!
Preparations for Installation
Please refer to the “Safety Information” section!
Keep a minimum distance of at least 1 m to lights, radiators and
other heat sources in order to avoid functional problems or faulty
switching.
Only install the motion detector on a stable surface.
The motion detector can be mounted on a wall in indoor and outdoor
areas. Pay attention to the correct mounting position. The side that
is shaped like a cover must always face upwards, otherwise water
might enter the product.
Function of the motion detector
The motion detector responds to temperature changes within the
detection range, e.g. if a person, an animal or a car with a different
temperature to the detection area enters the detection area.
To ensure optimal motion detection, the motion detector must be
placed so that the object to be detected does not approach the motion
detector directly but passes from left to right or vice versa. Mind this,
when installing the product.
The transmission range for the detection of a motion is determined
by several factors:
Mounting height of the motion detector
Temperature difference between the moving object and the
background (environment)
Size of the object
Distance of the object from the motion detector
Direction and speed of the movement
Ambient temperature
Installation
The wall bracket can be fastened to the wall using 2 screws. Use,
depending on the mounting location, appropriate screws and if
necessary dowels.
Pay attention when drilling and tightening the screws that no cable or
pipes are damaged.
The motion detector is slided from above onto the wall bracket. By
means of the wall bracket’s exible head the motion detector can be
aligned to the required detection range.