Manual

Programming
The included transponder is normally paired as a master transponder and can be used to pair/save or delete
user transponders and user ngerprints.
In the section below you will nd instructions on how to pair a master ngerprint.
a) Pairing a new master transponder and/or master ngerprint
A new master transponder can be paired if the currently used master transponder is lost or
defective. There can be only one master transponder for security reasons (if a lost master tran-
sponder “shows up”, it will no longer be recognised).
You can save a master ngerprint or a master transponder or both.
Switch off the power supply and wait until the LED goes off.
Press and hold down the door opener button and switch on the power supply. You will hear a beep (the
LED briey ashes red and green) and then the LED lights up red. Now release the door opener button.
You will hear another beep and the LED lights up yellow.
If you hear two beeps, you have waited too long. Switch off the power supply and start over.
To save a master ngerprint, place the same nger three times on the sensor. As your nger touches the
sensor, an LED ring around the sensor lights up blue. The LED ring lights up green and you will hear a
beep when the ngerprint has been correctly recognised.
If the ngerprint cannot be read correctly, you will hear three beeps and the LED ring will ash
red. The same applies if you attempt to use a stored ngerprint as the new master ngerprint.
To save a new transponder as a master transponder, hold the transponder in front of the sensor until you
hear a beep. The new master card is saved.
Once the master ngerprint and the master transponder have been saved, the programming mode is
exited and the LED lights up red. When only one of the two types of access is used, wait a few seconds
until the programming mode is automatically exited and the LED lights up red.
b) Saving a user transponder/ngerprint
Hold the master transponder once in front of the sensor or place the master nger once on the ngerprint
sensor. You will hear a beep and the LED lights up yellow. The pairing mode is enabled.
Now pair a single user transponder or several user transponders one after another. You will hear a beep
once every single user transponder is paired.
If a newly paired transponder is used, you will hear three beeps and the LED ashes red.
To pair a user ngerprint, place the same nger three times in succession on the ngerprint sensor. As your
nger touches the sensor, an LED ring around the sensor lights up blue. The LED ring lights up green and
you will hear a beep when the ngerprint has been correctly recognised.
If the ngerprint cannot be read correctly, you will hear three beeps and the LED ring will ash
red. The same applies if you attempt to read a stored ngerprint.
Hold the master transponder once in front of the sensor or place the master nger once on the ngerprint
sensor. You will hear a beep and the LED lights up red. The pairing mode is disabled.
If no transponder or ngerprint is paired within 10 seconds, the pairing mode is automatically
exited.
c) Deleting the user transponder
Hold the master transponder twice in front of the sensor or place the master nger twice on the ngerprint
sensor. Each time you hold it you will hear a beep and the LED lights up yellow. The delete mode is
enabled.
Hold the user transponder (or several user transponders one after another) you want to delete in front of
the sensor. You will hear a beep once every single user transponder is deleted.
If a newly deleted transponder is used, you will hear three beeps and the LED ashes red.
To delete a user ngerprint, place your nger on the ngerprint sensor. As your nger touches the sensor,
an LED ring around the sensor lights up blue. The LED ring lights up green and you will hear a beep when
the ngerprint has been deleted.
Hold the master transponder once in front of the sensor or place the master nger once on the ngerprint
sensor. You will hear a beep and the LED lights up red. The delete mode is disabled.
If no transponder or ngerprint is deleted within 10 seconds, the delete mode is automatically
exited.
d) Setting relay switching time
By default, the relay is activated for 5 seconds when a paired user transponder/ngerprint is
read. This time can be adjusted from 1 to 99 seconds and toggle mode (relay switches upon
each reading) can be selected.
Switch off the power supply and wait until the LED goes off.
Press and hold down the door opener button and switch on the power supply. As you hold down the button,
you will hear a beep. You should release the door opener button after two beeps. You will then hear a long
beep and the LED lights up yellow; the relay setting mode is enabled.
If you do not perform any further actions within 10 seconds, you will hear three beeps and the
LED ashes red. The relay setting mode is disabled automatically.
Switching to toggle mode
Keep the door opener button pressed until you hear three beeps. Now release the door opener button. The
relay setting mode is now disabled.
When a paired user transponder/ngerprint is read, the relay switches and remains in current switch posi-
tion until another user transponder/ngerprint is read.
Setting the relay switching time
Keep the door opener button pressed until you hear three beeps. As you hold down the button, you will
hear a beep every second. The relay is activated for one second with a beep (time can be adjusted from
1 to 99 seconds).
Release the door opener button when the required time has been reached (for example, if you release it
after 8 beeps, the relay will be activated for 8 seconds when a paired user transponder/ngerprint is read).
The relay setting mode is now disabled.
e) Resetting to factory defaults
Switch off the power supply and wait until the LED goes off.
Press and hold down the door opener button and switch on the power supply. As you hold down the button,
you will hear a beep. After a while, you will hear two beeps followed by another three beeps. Now release
the door opener button: the LED lights up yellow.
Now press and hold down the door opener button for 10 seconds until you hear a long beep: the LED
briey lights up green and red. The access system is now reset to factory defaults. All stored data (tran-
sponders/ngerprints) are deleted and the relay switching time is reset to 5 seconds.
You must rst pair a new master transponder and/or master ngerprint before you can save user
transponders/ngerprints.
Care and cleaning
Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may damage the
casing or cause the product to malfunction.
Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable waste and must not be placed in household waste. At the end
of its service life, dispose of the product in accordance with applicable regulatory guidelines. You
thus full your statutory obligations and contribute to environmental protection.
Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declares that this product con-
forms to Directive 2014/53/EU.
Click on the following link to read the full text of the EU Declaration of Conformity:
www.conrad.com/downloads
Enter the product's order number in the search eld; you can then download the EU Declaration
of Conformity in the available languages.
Specications
Operating voltage ......................................9 - 24 V/DC
Power consumption ...................................Standby <25 mA; max. 100 mA
Transmission frequency range ..................124.6 - 125.4 kHz
Transmission power...................................11.62 dBm
Max. reading distance ............................... approx. 2 cm
Data retention in case of a power cut ........yes
Suitable transponders ................................Commercially available EM transponders for frequency 125 kHz
Output ........................................................Potential-free single-pole changeover contact (relay)
Max. contact rating 24 V/DC, 2 A
Adjustable switching duration (1 - 99 seconds or toggle mode;
5 seconds by default)
Transponder storage .................................3000
Transponder storage .................................100
Mounting location ...................................... Indoors/outdoors
Protection class .........................................IP66
Ambient conditions ....................................Temperature -40 °C to +60 °C
Dimensions ................................................115 x 40 x 25 mm (H x W x D)
Weight ....................................................... approx. 105 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE. *2380476_V1_0921_02_VTP_m_en