Datasheet

Rev. D, April 05.
Page 2 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS,
OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS
BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE.
TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
2.2.3. Shelf life (Reversible Capacity):
The table below describes the shelf life at different storage temperatures to 80% of initial
capacity specified at paragraph 2.2.1.
Temperature HLC used
independently
HLC in Pulses Plus battery
RT 3 years 10 years
60°C 4 weeks 7 years
85°C 1 week At least 1 year
2.2.4. Self discharge current in Pulses Plus™ battery:
At RT: 1µA
At 80
o
C: 5µA
2.2.5. Number of charge-discharge cycles to 80% of initial capacity :
100% DOD 10% DOD 1% DOD
Charged to
3.67V
4000 40,000 400,000
Charged to
3.90V
1000 10,000 100,000
DOD (Depth Of Discharge)
2.2.6. Cell impedance: Less than 250 mOhm (at RT @ 1kHz)