13.6 I/O Electrical and Timing Characteristics
Parameters Conditions Min. Typ. Max. Unit Comments
I/Ox input voltage low 0 0.8 V
I/Ox input voltage high 2 V
I/Ox input current 1 µA
I/Ox output voltage low V
I/Ox output voltage high V
I/Ox output current mA
Sunk or
sourced
I/Ox output capacitance pF
tCV (time to change value)
End of reception on
RX to I/Ox level
changed
35 40 µs
tGV (time to get value)
End of reception on
RX to I/Ox level
read
33 38 µs
tFR (time to fall or rise) Fall/rise time 10 25 ns
Figure 24: I/O DC Characteristics and Timing
RX_RS232
IOx
Output
IOx
Input
t
CV
t
FR
t
GV