Improperventingofthisappliancecanresultinexcessivelevelsofcarbonmonoxide
whichcanresultinseverepersonalinjuryordeath.
Wheninstallingtheventsystem,allapplicablenationalandlocalcodesmustbe
followed.Ifyouinstallthimbles,firestopsorotherprotectivedevicesandthey
penetrateanycombustibleornoncombustibleconstruction,besuretofollowall
applicablenationalandlocalcodes.
TH2DVINSTALLATION
TH2DV is equipp ed with a thermistor and hilimit switch for the exhaust gas, detecting excess
temperatures within the flue and enabling the unit to safely stop operations if needed.
These
components are always monitoring exhaust gas conditions in order to prev ent heat damage to PVC
(Plastic)ventingifPVCisused.
If the exhaust gas temperature exceeds 140°F, these components will enable the unit to safely sto p
operations.(For the TH2OS model, these components are not available since there’s no exhaust
ventingrequired.)
TH2DVrequiresa4”makeupintakeairsupply
pipe.Theintakepipemustbesealedairtight.
Air supply pipe can be made of ABS, PVC,
galvanized steel, corrugated stainless steel,
orCategorylll/IVstainlesssteel.
Sidewall ventingis recommended for
the TH2
DV. Vertical venting (roof
termination)isacceptable.
TAKAGI recommends running the
exhaust vent and the intake pipe as
parallelaspossible.
TheTHPA01adaptorisusedtomake
theconnectionbetween theTH2DV
vent collar and PVC vent pipe easier
andformaintenancepurposes.

VENTINGINSTRUCTIONS
General
TheTH2DVmustbeventedinaccordancewiththesection“VentingofEquipment"ofthelatestedition
of the Natural Fuel Gas Code: The ANSI Z223.1, All applicable local building codes, Section 7 of the
CAN/CSAB149.1NaturalGasinCanada,PropaneInstallationCodeinCanada.
The use of venting materials approved for Category III/ IV appliances is recommended whenever
possible. However, TH2DV may also be vented with plastic pipe materials such as PVC. For details ,
pleaserefertotheExhaustVent(PVCVent)sectiononp.13.VentinstallationsinCanadawhichutilize
plastic
ventsystemsmustuseventingthatcomplieswithULCS636.
WARNING
Top12”
Side3”
Back0.5”
Side3”
Front4”
(24”Recommended
forMaintenance)
Bottom12”