Installation Manual

Installation
11Page
Exhaustvent(PVC&ABSvent)‐
TheTH2DVcanbeconnectedwithPVCorABSventing(temperatureratedupto149°F).However,
TAKAGIrecommendsPVC(orABS)ventingcertifiedtoULCS636s t andards.
Item Material UnitedStates Canada
Exhaustpipe&
Fittings
Schedule40PVC ANSI/ASTMD1785
ULCS636Certified
MaterialsOnly
PVCDWV ANSI/ASTMD2665
Schedule40CPVC ANSI/ASTMF441
Schedule40ABSDWV ANSI/ASTMD2661
PipeCement/Primer
PVC ANSI/ASTMD2564
CPVC ANSI/ASTMF493
ABS ANSI/ASTMD2235
NOTE:DoNOTUseCellularFoamCorePipe
The maximum length of exhaust vent piping must not exceed 50 ft. (deducting 5 ft. for each
elbowusedintheventingsystem).Donotusemorethan5elbows.
Whenthehorizontalventrunexceeds5ft.,supporttheventrunat3ft.intervals withoverhead
hangars.
Diameter Max.No.ofElbow Max.Vertical&Horizontal(Total)VentLength
4” 5 50ft.
*Foreachelbowadded,deduct5ft.frommax.Ventlength.
No.ofElbows Max.VerticalorHorizontalLength
0 50ft.
1 45ft.
2 40ft.
5 25ft.
FordetailsontheventconnectiontotheTH2DV,refertoP.13.
Exhaustvent(Stainlesssteelvent)‐
This is a Category IV appliance and must be vented accordingly . The vent system must be sealed air
tight.Allseamsandjointswithoutgasketsmustbesealedwithhighheatresistant siliconesealantorUL
listedaluminumadhesivetapehaving aminimumtemperatureratingof160°F.Forbestresults,a
vent
systemshouldbeasshortandstraightaspossible.
This TH2DV is a Category IV appliance and must be vented accordingly with any 4” vent
approvedforusewithCategoryIII/IVorSpecialBHtypegasvent.
TAKAGI recommends the “TVent” line
manufactured by TAKAGI (Refer to Takagi’s “TVent
brochurefordetails).However,thefollowingarealsoULlistedma nufacturers:ProTechSystems
Inc.(FasNSeal),FlexLInc.,ZFlexInc.(ZVentIII),MetalFabInc.,andHeatFabInc.(SafTVent).
Followtheventpipemanufacturer’sinstructionswheninstalling
theventpipe.