Installation Manual

Installation
16Page
Additionalclearances‐
Pleasefollowalllocalandnationalcodesinregardstoproperterminationclea rances.Intheabsenceof
suchcodes,thefollowingclearancescanbeusedasguidelines.Localcodessupersedetheseguidelines.
Forsidewallterminations
Exhausttermination
1ft.
1ft.
2ft.
Inside
corner
Formultiplesidewallexhaust
terminations(e.g.multiunit
systems),anexhausttermination
mustbeatleast1ft.awayfrom
anotherexhaustterminati on.An
exhaustterminationmustalsobe
atleast2ft.awayfromaninside
corner(iftheadjacentwallisless
than2ft.oflength,theminimum
requireddistanceawayfromthe
insidecornerwillbeequaltothe
lengthofthatadjacentwall).
Fordirectventsidewall
terminationsthatusetwo
separatepenetrationsforthe
intakeandexhaust,distance
theintakeandexhaust
terminationsatleast3ft.away
fromeachother,nomatterthe
orientation.
Formultipleunit,directventsidewall
terminationsthatcombinetheintake
andexhaustintoasinglepenetration,
spaceeachdirectventterminationat
least1ft.awayfromeachother,no
mattertheorientation.Adirectvent
terminationmustalsobeatleast2ft.
awayfromaninsidecorner(if
the
adjacentwallislessthan2ft.of
length,theminimumrequired
distanceawayfromtheinsidecorner
willbeequaltothelengthofthat
adjacentwall).
Formultipleunitrooftopterminations(whetherforstandardindooror
directventinstallations)spaceallexhaustandintaketerminationsin
accordance
withlocalcodes.Anexhaustterminationmustbespacedfrom
awallorsurfaceinaccordancewithlocalcodesaswell.Intheabsenceof
suchacode,anexhaustterminationmustbeahorizontaldistanceofat
least2ft.awayfromawallorsurface.
A:inaccordancewith
localcodes
Forrooftopterminations
Airintake
Exhaust termination
A
A
A
A
A
2ft.
Airintake
Exhaust
termination
Exhaustand/ordirectvent
sidewallterminationsshould
beatleast2ft.awayfroman
oppositesurface/wall.Do
notplacethetermina tion
directlyinfrontofan
openingintoabuilding.
2ft.
Exhaust
termination
Airsupplyinlet
3ft.
3ft.
3ft.
Directventtermination
1ft.
1ft.
Inside
corner
2ft.