Installation Manual

Installation
17Page
1. Turnoffallelectricpowertothewaterheaterifserviceistobeperformed.
2. Turnthemanualgasvalvelocatedontheoutsideoftheunitclockwise3totheoffposition.
Ensure that any and all gas regulators used are operating properly and
providing gas pressures within the specified range shown below. Excess gas
inletpressuremaycauseseriousaccidents.
Conversion of this unit from natural gas to propane or vise versa cannot be
doneinthefield.Contactyourlocaldistributortogetthecorrectunitforyour
gas type. Conversion done by anyone other than the manufacturer or Takagi
Service Representative will void all warranty.Takagi is not liable
for any
propertyand/orpersonaldamageresultingfromunauthorizedconversions.
GASSUPPLYANDGASPIPESIZING
*Checkthatthetypeofgasmatchestheratingplatefirst.
1. Theminimumandmaximuminletgaspressuresare:
Gastype Inletgaspressure
NaturalGas Min.5.0”WCMax.10.5”WC
PropaneGas Min.8.0”WCMax.14.0”WC
2. Gas pressure below this specified range for the TH2DV/TH2OS and/or insufficient gas volume
willadverselyaffectperformance.ThesepressuresaremeasuredwhentheTH2DV/TH2OSisin
fulloperation.
3. Inletgaspressure mustnot exceedthe abovemaximumvalues;gas pressureabove
thespe cified
rangewillcausedangerousoperating conditionsanddamagetotheunit.
4. Until testing of the main gas line supply pressure is completed, ensure the gas line to the TH2
DV/TH2OSisdisconnectedtoavoidanydamagetothewaterheater.
Measuringinletgaspressure‐
TheTH2DV/TH2OScannotperformproperlywithoutsufficientinletgaspressure.Beloware
instructionsonhowtochecktheinletgaspressure.THISISONLYTOBEDONEBYALICENSED
PROFESSIONAL.
1. Shutoffthemanualgasvalveonthesupplygasline .
2. Removethe
screwforthepressureportlocatedonthegas
inletoftheTH2DV/TH2OSshowninthediagramtothe
right.
3. Connectthemanometertothepressureport.
WARNING
TOTURNOFFGASTOAPPLIANCE