PUMPCONTROLMODES
TheTH2DV/TH2OSprovidesthefourtypesofthepumpcontrol
modes.Thepumpcontrolmodesareselectedbychanging
dipswitchsettings.Thedipswitchesthatchangethepumpcontrol
modesarelocatedintherightbankofdipswitchesintheupper
leftquadrantofthecomputerboardin
theTH2DV/TH2OS.(See
right.)These4modesonlyaffectpumpsthatareconnectedto
theTH2DV/TH2OSpumpcontrol(p.25)
A)RecirculationControl:No.5ON
Feature:Maintainingtemperatureinastandardrecirculationloop,providinghotwaterinaquicker
amountoftime.
Function:Thepumpisonlysettorunwhenthetemperatureofthewaterintherecirculationloopis
morethan9°FbelowthesettemperatureoftheTH2DV/TH2OS.

Thepumpwillrunforabout1minuteevery30minutestodeterminewhetherthewater
temperatureintheentirerecirculationloopismorethan9°Fbelowthesettemperature.
Ifthewatertemperatureismorethan9°Fbelowthesettemperature,thepumpwillremainrunning
untilthewater
intheloopreachesthesettemperature.Otherwise,thepumpwillstopforanother
30minutes.
Iftheinletthermistorofwaterheatersdetectsthat thewatertemperatureismorethan9°Fbelow
thesettemperaturebeforethose30minuteshaveelapsed,thepumpwillactivateimmediatelyand
remainrunninguntil
thewaterintheloopreachesthesettemperature.
B)StorageTankCirculationControl:No.6ON
Feature:Thisistoensureahigherrateofrecoveryforstoragetankapplications.
Function: The TH2DV/TH2OS heats the water 5.4°F higher than its set temperature. The
circulation pump between the storage tank and the water heater will continually remain running.
After set temperature has been
reached in the storage tank, the TH2DV/TH2OS will fire off and
limit thewater flowrate to lessthan 2.6GPM, to continually monitor the temperaturethroughout
thesystem.
Note:Inthismode,thepumpwillcontinuallyremain running.
C)EnergyConservingRecirculation:No.5andNo.6ON
Feature:OperatessimilarlytothestandardRecirculationControlmode,butsavesmoreenergyby
limitingthetemperaturewithintherecirculationloop.
Function:Thetemperatureoftherecirculationloopisneverkeptabove120°F(49°C),regardlessof
thesettemperatureoftheTH2DV/TH2OS.
Rightbankofdipswitches