Installation Manual
NormalOperation
37│Page
• TheT‐H2‐DV/T‐H2‐OSwilldisplaythesettemperatureonthe3‐digit7‐
Seg. LED on the computer board.This LED is visible through a small
windowontheunit’sfrontcover.
• If the TM‐RE30 is installed, refer to the TM‐RE30 Installation Manual
included
withtheremoteforsettingtemperature.
T‐H2‐DV/T‐H2‐OS
• FlowratetoactivatetheT‐H2‐DV/T‐H2‐OS:0.5gallonperminute
• FlowratetokeeptheT‐H2‐DV/T‐H2‐OSrunning:0.4gallonperminute
HotWatertemperaturesover125°Fcancause severeburns instantly
ordeathfromscalding.
• The outlet hot water temperature of the T‐H2‐DV/T‐H2‐OS water
heaterisfactorysetat120°F.
• Feelthewatertemperaturebeforebathingorshowering.
NORMALOPERATION
GENERAL
1. Openahotwatertap.
2. Mixcoldwaterwiththehottoget
thecorrecttemperaturewater.
3. Closethehotwatertap.
WARNING
TEMPERATURESETTINGS
‐ONTHET‐H2‐DV/T‐H2‐OS‐
OnT‐H2‐DV/T‐H2‐OS,changingthetemperaturesettingcanbedonesimplybyusingthe3‐digit7‐seg.
LED,andthe“Increase”&“Decrease”buttonsonthecomputerboard(TM‐RE30remotecontrollerisnot
required)
WARNING