Installation Manual

NormalOperation
39Page
Onlypipeswithinthewaterheaterareprotectedbythefreezeprotection
system.Anywaterpipes(hotorcold)locatedoutsidetheunitwillnotbe
protected.Properlyprotectandinsulatethesepipesfromfreezing.
HouseholdFlowRates
TakenfromUPC2006
FLOW
TheflowratethroughtheTH2DV/TH2OSislimitedtoamaximumof9.0GPM.
Thetemperaturesetting,alongwiththesupplytemperatureofthewaterwilldeterminetheflow
rateoutputoftheunit.
Pleaserefertothetemperaturevs.gallonsperminutechart
onp.50todeterminethelikelyflow
ratesbasedonyourlocalgroundwatertemperatureandyourdesi redoutletwatertemperature
combination.
BasedontheUnitedStatesDepartmentofEnergy
methodoftestingwaterheateroutput,theTH2DV/T
H2OSisratedfor285gallonsper
hour(GPH)or4.8
gallonsperminute(GPM)forNaturalGas,and285GPH
or4.8GPMforLiquidPropane,whenraisingthewater
temperatureby77°F(from58°Fto135°F).
Refertothecharttotheri ghtfortypicalhousehold
plumbingfixtureflowratestodetermine
whattheTH2
DV/TH2OScandoinahouseholdapplication.
FREEZEPROTECTIONSYSTEM
Thisunitcomesequippedwithheatingblockstoprotectitagainstdamagesasso ciatedwithfreezing.
Forthisfreezeprotectionsystemtooperatetherehastobeelectricalpowertotheunit.Damageto
the heat exchanger caused by freezing temperatures due to po wer loss is not covered under the
warranty.Incaseswherepowerlossescanoccur,considertheuseofabackuppowersupply.
Thefreezeprotectionsystemwill activatewhenthesurrounding and/or outside temperaturesdrop
below36.5°F(2.5°C).
Inanyareassubjecttofreezingtemperatures,TAKAGIhighlyrecommendsanindoorinstallationwith
theT
H2DVmodel.Insuchaninstallation,freezing issuescanonlyoccur ifcoldairentersthrough
theventingintotheheatexchanger,whetherbynegativepressureswithintheinstallationlocationor
by strong outside winds.It is the installer’s responsibility to be aware of these issues and take all
preventative
measures.TAKAGIwillnotbe responsible foranydamageto theheatexchangerasa
resultoffreezing.
TAKAGIalsohighlyrecommendstheuseofabackflowventdampertominimizetheamountofcold
airenteringthroughtheexhaustventingwhenthewaterheaterisoff.
Ifyouwillnotbeusingyourheaterforalongperiodoftime:
1. Completelydraintheunitofwater.Refertop.40.
2. Disconnectpowertoyourheater.
Thiswillkeepyourunitfromfreezingandbeingdamaged.
Appliance/Use FlowRate(GPM)
LavatoryFaucet 1.0
BathTub 4.010.0
Shower 2.0
KitchenSink 1.5
Dishwasher 1.5
Washingmachine 4.0