Installation Manual

NormalOperation
40Page
DrainPlug
withFilter
WaterValve
DrainPlug
(Small)
GasValve
Turnofftheelectricalpowersupplyandclosethemanualgascontrol
valveandthemanualwatercontrolvalvebeforeservicing.
DrainPlug
(Large)
MAINTENANCEANDSERVICE
Cleanthecoldwaterinletfilter.(Refertodiagrambelow)
Besurethatallopeningsforcombustionandventilationairarenotblocked.
Checkthattheexhaustventpipeisnotblocked.
Checkthegaspressure.
Keep the area around the water heater clear. Remove
any combustible materials, gasoline or any
flammablevaporsandliquids.
TAKAGIrecommendshavingtheunitcheckedonceayearorasnecessarybyalicensedtechnician.If
repairsareneeded,anyrepairsshouldbedonebyalicensedtechnician.
UNITDRAININGandFILTERCLEANING
1. Closethemanual gasshutoffvalve.
2. Turnoffpowertotheunit,andthenturnonagain.
3. Wait30seconds,andthenturnoffpowertotheunit,
yetagain.
4. Closethewatershutoffvalve.
5. Open all hot water taps in the house. When
the
residual water flow has ceased, close all hot water
taps.
6. Have a bucket or pan to catch the water from the
unit’sdrainplugs.Unscrew
thetwodrainplugs(Large
andsmall)todrainallthewateroutoftheunit.
7. Wait a few minutes to ensure all water has
completelydrainedfromunit.
8. Clean the filter:Check thewater filterlocatedwithin
thecoldinlet.Withatinybrush,cleanthewater
filter
of any debris which may have accumulated and
reinsertthefilterbackintothecoldwaterinlet.
9. Securelyscrewthedrainplugsbackintoplace.Hand
tightenonly.
WARNING