Installation Manual
NormalOperation
40│Page
DrainPlug
withFilter
WaterValve
DrainPlug
(Small)
GasValve
Turnofftheelectricalpowersupplyandclosethemanualgascontrol
valveandthemanualwatercontrolvalvebeforeservicing.
DrainPlug
(Large)
MAINTENANCEANDSERVICE
• Cleanthecold‐waterinletfilter.(Refertodiagrambelow)
• Besurethatallopeningsforcombustionandventilationairarenotblocked.
• Checkthattheexhaustventpipeisnotblocked.
• Checkthegaspressure.
• Keep the area around the water heater clear. Remove
any combustible materials, gasoline or any
flammablevaporsandliquids.
TAKAGIrecommendshavingtheunitcheckedonceayearorasnecessarybyalicensedtechnician.If
repairsareneeded,anyrepairsshouldbedonebyalicensedtechnician.
UNITDRAININGandFILTERCLEANING
1. Closethemanual gasshutoffvalve.
2. Turnoffpowertotheunit,andthenturnonagain.
3. Wait30seconds,andthenturnoffpowertotheunit,
yetagain.
4. Closethewatershutoffvalve.
5. Open all hot water taps in the house. When
the
residual water flow has ceased, close all hot water
taps.
6. Have a bucket or pan to catch the water from the
unit’sdrainplugs.Unscrew
thetwodrainplugs(Large
andsmall)todrainallthewateroutoftheunit.
7. Wait a few minutes to ensure all water has
completelydrainedfromunit.
8. Clean the filter:Check thewater filterlocatedwithin
thecoldinlet.Withatinybrush,cleanthewater
filter
of any debris which may have accumulated and
reinsertthefilterbackintothecoldwaterinlet.
9. Securelyscrewthedrainplugsbackintoplace.Hand‐
tightenonly.
WARNING