Installation Manual

Troubleshooting
41Page
GENERAL
TROUBLESHOOTING
PROBLEM SOLUTIONS
TEMPERATUREandAMOUNTOFHOTWATER
Ittakeslongtimetoget
hotwateratthe
fixtures.
ThetimeittakestodeliverhotwaterfromtheTH2DV/TH2OS
toyourfixturesdependsonthelengthofpipingbetweenthetwo.
Thelongerthedistanceorthebiggerthepipes,thelonger
itwill
taketogethotwater.
Ifyouwouldliketoreceivehotwatertoyourfixturesquicker,you
maywanttoconsiderahotwaterrecirc ulationsystem.(p.32)
Thewaterisnothot
enough.
Comparetheflowandtemperature.Seethechartonp.50.
Checkcrossplumbingbetweencoldwaterlinesandhotwater
lines.
Isthegassupplyvalvefullyopen?(p.34)
Isthegaslinesizedproperly?(p.18)
Isthegassupplypressureenough?
(p.17)
Isthesettemperaturesettoolow?(p.37,38)
Thewateristoohot.
Isthesettemperaturesettoohigh?(p.37,38)
Thehotwaterisnot
availablewhenafixture
isopened.
Makesuretheunitgets120V60Hzpowersupply.
Ifyouareusingtheremotecontroller,isthepowerbuttonturned
on?
Isthegassupplyvalvefullyopen?(p.34)
Isthewatersupplyvalvefullyopen?(p.34)
Isthefilteroncold
waterinletclean?(p.40)
Isthehotwaterfixturesufficientlyopentodrawatleast0.5GPM
throughthewaterheater?(p.37)
Istheunitfrozen?
Isthereenoughgasinthetank?(forLP)
Thehotwaterturns
coldandstayscold.
IstheflowrateenoughtokeeptheTH2DV/TH2OSrunning?(p.
37)
Ifthereisarecirculationsysteminstalled,doestherecirculation
linehaveenoughcheckvalves?
Isthegassupplyvalvefullyopen?(p.34)
Isthefilteroncoldwaterinlet
clean?(p.40)
Arethefixturescleanofdebrisandobstructions?
Fluctuationinhotwater
temperature.
Isthefilteroncoldwaterinletclean?(p.40)
Isthegaslinesizedproperly?(p.18)
Isthesupplygaspressureenough?(p.17)
Checkforcrossconnectionbetweencoldwaterlinesandhotwaterlines.