PROBLEM SOLUTIONS
‐WATERHEATER‐
Unitdoesnotignitewhenwater
goesthroughtheunit.
Istheflowrateover0.5GPM?(p.37)
Checkforthefilteroncold waterinlet.(p.40)
Checkforreverseconnectionandcrossconnection.
Ifyouusetheremotecontroller,isthepowerbutton
turnedon?
Thefanmotorisstillspinning
afteroperationhasstopped.
Thisisnormal.Afteroperationhasstopped,thefanmotor
keepsrunningfor35secondsinordertoreignitequickly,
aswellaspurgealltheexhaustgasoutoftheflue.
Abnormals oundscom efrom
theunit.
ContactTAKAGI.
TMRE30(OPTIONAL)
Remotecontrollerdoesnot
displayanythingwhenthe
powerbuttonisturnedon.
PresstheON/OFFbutton.
Ifthelamplightsup
Thisisnormal.Whentheunithasnotoperatedforfive
minutesormore,thedisplayturnsofftoconverseenergy.
Ifthelampdoesnotlight
Makesuretheunithaspowersupply.
Makesuretheconne ctiontotheunit iscorrect.(p.24)
AnERRORcodeisdisplayed.
Pleaseseep.43.
EASYLINKSYSTEM
Howaretheunitnumbers
assigned?
ForanEasyLinksystem,theMasterunitisalwayslabeled
#1andallothersubsequenceSlaveunitsarenumbered
randomly.
TocheckwhichnumbersareassignedtowhichSlaveunits,
pushthebuttononthecomputerboardofanySlaveunit
as
shownbelow.Theunitnumberwillbedisplaye donthe
7SegLED.
Buttontocheck
unitnumbers
7SegLED