FAULTANALYSISOFERRORCODES‐
IfthereisaproblemwiththeinstallationortheTH2DV/TH2OS,itwilldisplayanumerical
errorcodeonthe7segLEDofthecomputerboardortheTMRE30(ifinstalled)to
communicatethesourceoftheproblem.
Error
Code
Malfunctiondescription Diagnosis
031
Incorrectdipswitchsettings
Check the dipswitch
settingsonPCB
101
Warningforthe“991”errorcode
CallTAKAGI
TechnicalDept.
at18888825244
111
Ignitionfailure
Checkgassupply
121
Lossofflame
311
Outputthermistorfailure
CallTAKAGI
TechnicalDept.
at18888825244
321
Inletthermistorfailure
331
Mixingthermistorfailure
341
Exhaustthermistorfailure(OnlyTH2DV)
391
Ai
r
fuelRatioRodFailure
441
FlowSensorFailure(OnlyEasyLinksystem)
510
AbnormalMainGasValve
551
AbnormalGasSolenoidValve
611
FanMotorFault
621
ExhaustfanmotorFault(OnlyTH2DV)
631
AbnormalExternalPump
651
WaterControlValveFault(FlowAdjustmentfunction)
(OnlyEasyLinksystem)
661
WaterControlValveFault(Bypassvalvefunction)
701
ComputerboardFault
711
GasSolenoidValvedrivecircuitfailure
721
FalseFlameDetection
741
Miscommunication between TH2DV/TH2OS and
TMRE30
761
MiscommunicationinEasyLink
941
Abnormalexhausttemperature (OnlyTH2DV)
991
Imperfectcombustion