Installation Manual
Troubleshooting
44│Page
‐FAULTANALYSISOFERRORCODES‐
IfthereisaproblemwiththeinstallationortheT‐H2‐DV/T‐H2‐OS,itwilldisplayanumerical
errorcodeonthe7‐segLEDofthecomputerboardortheTM‐RE30(ifinstalled)to
communicatethesourceoftheproblem.
Error
Code
Malfunctiondescription Diagnosis
031
Incorrectdipswitchsettings
Check the dipswitch
settingsonPCB
101
Warningforthe“991”errorcode
CallTAKAGI
TechnicalDept.
at1‐888‐882‐5244
111
Ignitionfailure
Checkgassupply
121
Lossofflame
311
Outputthermistorfailure
CallTAKAGI
TechnicalDept.
at1‐888‐882‐5244
321
Inletthermistorfailure
331
Mixingthermistorfailure
341
Exhaustthermistorfailure(OnlyT‐H2‐DV)
391
Ai
r
‐fuelRatioRodFailure
441
FlowSensorFailure(OnlyEasy‐Linksystem)
510
AbnormalMainGasValve
551
AbnormalGasSolenoidValve
611
FanMotorFault
621
ExhaustfanmotorFault(OnlyT‐H2‐DV)
631
AbnormalExternalPump
651
WaterControlValveFault(FlowAdjustmentfunction)
(OnlyEasy‐Linksystem)
661
WaterControlValveFault(Bypassvalvefunction)
701
ComputerboardFault
711
GasSolenoidValvedrivecircuitfailure
721
FalseFlameDetection
741
Miscommunication between T‐H2‐DV/T‐H2‐OS and
TM‐RE30
761
MiscommunicationinEasy‐Link
941
Abnormalexhausttemperature (OnlyT‐H2‐DV)
991
Imperfectcombustion