T-H3 Installation Manual

36 Page
4.
Tighten the two Fork terminals beneath the two Remote controller terminal screws on the back
of the main body. (Fig. D-1)
5.
Cut out the inlet for the remote controller cable from the bottom of the main body. (Fig. D-2)
6.
Place the Main body back on the Back plate, with the Remote controller cable running out of
the bottom inlet.

1.
Disconnect power supply from the water heater.
2.
Take off the water heater’s front cover.
3.
Locate the two terminals for the remote controller in the water heater. (Refer to the Fig. E-1 and
E-2.)
4.
Take off the back plate from the remote controller, and then attach the two fork terminals to
the connector base on the back side of the remote controller with two screws. Make sure the
terminals are firmly fixed. (See the above instructions for installation of the remote controller.)
5.
Pull the remote controller cable through the hole at the bottom of the water heater’s casing.
6.
Secure both controller cable terminals to the terminals on the computer board as shown below.
(Secure them underneath the screw terminals. No polarity.)
* Do NOT jump or short-circuit the cables, or computer will be damaged.
7.
Replace the front cover securely.
Remote controller
terminals
Fig. D-1
Two fork terminals
Remote controller cable
Inlet for the remote
controller cable
Cut out
Fig. D-2
Installaon
Installaon Manual
240 and 340 models
100209924
(TM-RE42)
Connect other end to these terminals
Fig. E-1
100209924
(TM-RE42)
Connect other end to these terminals
540 model
Fig. E-2