CLEARANCES
Installaon
Installaon Manual
Model Top Bottom Front Back Sides
240 Indoor
340 Indoor
540 Indoor
12 in.
(305 mm)
12 in.
(305 mm)
4 in.*
(102 mm)
0.5 in.
(13 mm)
3 in.
(76 mm)
240 Outdoor
340 Outdoor
540 Outdoor
36 in.
(914 mm)
12 in.
(305 mm)
24 in.
(610 mm)
0.5 in.
(13 mm)
3 in.
(76 mm)
*24 inches recommended for maintenance.
OPTIONAL ITEMS
Back
Side
Front
Side
Top

#
Model
240
Indoor
240
Outdoor
340
Indoor
340
Outdoor
540
Indoor
540
Outdoor
1.
Temperature remote
controller
2.
Pipe cover
3.
Neutralizer kit
4.
Sidewall vent
terminator (Hood)
and Wall thimble
5.
3" PVC concentric
termination
6.
Non-return valve
7.
PVC Adapter
INCLUDED ACCESSORIES
Check that these items below are included with the water heater.
Installation manual
and owners guide
Temperature remote controller kit*
Outdoor models only
Bird screen
Indoor models only
Communication cable
540 model only
Qty: 1
Qty: 1
Qty: 1
*Refer to p. 10 and 35.
Qty: 2
100209924
(TM-RE42)
Maintain all clearances around the water
heater. Failure to do so could create a fire
hazard, potentially leading to death, serious
injury, and/or property damage.
WARNING