Product Brochure

COMMERCIAL, INDUSTRIAL AND RESIDENTIAL ELECTRICAL PRODUCTS
www.TayMac.com www.TayMac.com
What has changed in the code for 2014
What does this mean?
All Covers installed in a Wet Location that are using a 15 or 20 amp
receptacle must use a While-In-Use cover and must meet “Extra Duty”.
NATIONAL ELECTRICAL CODE 2014 EDITION
406.9 Receptacles in Damp or Wet Locations.
(A) Damp Locations. A receptacle installed outdoors in a
location protected from the weather or in other damp locations
shall have an enclosure for the receptacle that is weatherproof
when the receptacle is covered (attachment plug cap not
inserted and receptacle covers closed).
An installation suitable for wet locations shall also be
considered suitable for damp locations.
A receptacle shall be considered to be in a location protected
from the weather where located under roofed open porches,
canopies, marquees, and the like, and will not be subjected to a
beating rain or water runoff. All 15- and 20-ampere, 125- and
250-volt nonlocking receptacles shall be a listed weather-
resistant type.
Informational Note: The types of receptacles covered by this
requirement are identified as 5-15, 5-20, 6-15, and 6-20 in
ANSI/NEMA WD 6-2002, National Electrical Manufacturers
Association Standard for Dimensions of Attachment Plugs and
Receptacles.
(B) Wet Locations.
(1) Receptacles of 15 and 20 Amperes in a Wet Location.
15- and 20-ampere, 125- and 250-volt receptacles installed
in a wet location shall have an enclosure that is weatherproof
whether or not the attachment plug cap is inserted. An outlet
box hood installed for this purpose shall be listed and shall be
identified as “extra-duty.” All 15- and 20- ampere, 125- and
250-volt nonlocking-type receptacles shall be listed weather-
resistant type.
Informational Note No. 1: Requirements for extra-duty outlet box
hoods are found in ANSI/UL 514D-2000, Cover Plates for Flush-
Mounted Wiring Devices.
Informational Note No. 2: The types of receptacles covered by
this requirement are identified as 5-15, 5-20, 6-15, and 6-20
in ANSI/NEMA WD 6-2002, National Electrical Manufacturers
Association Standard for Dimensions of Attachment Plugs and
Receptacles.
Exception: 15- and 20-ampere, 125- through 250-volt
receptacles installed in a wet location and subject to routine
high-pressure spray washing shall be permitted to have an
enclosure that is weatherproof when the attachment plug is
removed.
1
bELL
®
EXtRA dUtY
®
mEtAL WhiLE-in-UsE covERs
Rain Chamber for
Extra Protection
from Splashing
Cord
Catch
Lid Fits
Large Electrical
Cords and Plugs
Fits Device
without
Adapter
Fits Full-Size
Padlock
5852-0
5802-0
5881-0
5861-0 5830-0 5885-0 5880-0 5876-0
CATALOG # DESCRIPTION DEPTH COLOR PKG. TYPE STD. PKG. UPC
1-Gang Extra Duty While-In-Use Covers
5881-0
Vertical GFCI 3" Gray Shrink 4 050169588109
5802-0
Horizontal GFCI 3" Gray Shrink 3 050169580202
5852-0
Vertical Duplex 3" Gray Shrink 4 050169585207
5861-0
Horizontal Duplex 3" Gray Shrink 3 050169586105
1-Gang Extra Duty Deep While-In-Use Covers
5830-0
Vertical 1.55" or 2.10" Single Round 4.5" Gray Shrink 3 050169583005
2-Gang Extra Duty While-In-Use Covers
5885-0
(2) GFCI 3" Gray Shrink 3 050169588505
5880-0
(2) Duplex 3" Gray Shrink 3 050169588000
5876-0
GFCI/Duplex 3" Gray Shrink 3 050169587607
•Superior commercial quality die-cast aluminum
•Unique lid design allows larger plugs and provides
more room for bend radius of electrical cords
•Cord catch prevents accidental pull outs
•Powder coated for corrosion protection
•Includes gasket and hardware for device or box
mounting
U.S. Patents: 8,013,245
2014 NEC & NEMA
3R Compliant