Information

INSTRUCTION MANUAL
RWS 50B600B Series
TDKLambda
TDKLambda
15/16
6.
Power Frequency Magnetic Field Immunity Test (IEC6100048)
MODEL : CCG304815D
(1) Equipment Used
ACパワーソース : 4420 (NF)
AC Power Source
ヘルムホルツコイル : HHS5215/10A (Schwarzbeck)
Helmholtz Coil
(2)
The Number of D.U.T. (Device Under Test)
CCG304815D : 1 (unit)
(3) Test Conditions
入力電圧 : 48VDC 力電圧 : 定格
Input Voltage Output Voltage Rated
出力電流 : 0% 100% 加磁界周波数 : 50Hz60Hz
Output Current Magnetic Frequency
周囲温度 : 25
o
C 印加方向 : XYZ
Ambient Temperature Direction
試験時間 : 10秒以上(各方向)
Test Time More than 10 seconds (each direction)
(4) Test Method
(5) Acceptable Conditions
1.試験中、5%を超える出力電圧の変動のない事
The regulation of output voltage must not exceed 5% of initial value during test.
2.試験後の出力電圧は初期値から変動していない事
The output voltage must be within the regulation of specification after the test.
3.発煙・発火のない事
Smoke and fire are not allowed.
CCG3048**D
DC input
Analog voltage meter
0.8m
Wooden table
1.5m
1
Helmholtz coil 1
Noise filter
D.U.T.
Load
2
Helmholtz coil 2
AC
AC power source
1.5m
GND plane