2.1 INPUT CHARACTERISTICS
GEN 8-300 10-240 16-150 20-120 30-80 40-60 60-40 80-30 100-24 150-16 300-8 600-4
1. Input voltage/freq. (*3) VAC
Single Phase,230V models: 170~265Vac, 47~63Hz
3-Phase, 208V models: 170~265Vac, 47~63Hz
2. Maximum
Input current
at 100% load
Single Phase,230V models:
A
17. 3 17. 3 17. 3 16.8 16.6 16.6 16.6 16.6 16.6 16.6 16.6 16.6
3-Phase, 208V models: 10.5 10.5 10.5 10.2 10.1 10.1 10.1 10.1 10.1 10.1 10.1 10.1
3. Power Factor (Typ) Single Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208Vac, rated output power.
4. Efficiency (*4) % 84 84 86 86 86 88 88 88 88 88 88 87
5. Inrush Current (*5) A Single-Phase and 3-Phase 208V models: Less than 50A
2.2 POWER SUPPLY CONFIGURATION
1. Parallel Operation Up to 4 identical units in master/slave mode
2. Series Operation Up to 2 identical units. with external diodes. 600V Max to Chassis ground
2.3 ENVIRONMENTAL CONDITIONS
1. Operating temp 0~50°C, 100% load.
2. Storage temp -20~85°C
3. Operating humidity 20~90% RH (non-condensing).
4. Storage humidity 10~95% RH (non-condensing).
5. Vibration MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface.
6. Shock Less than 20G , half sine , 11mSec. Unit is unpacked.
7. Altitude
Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
8. RoHS Compliance Complies with the requirements of RoHS directive.
2.4 EMC
1.Applicable Standards:
2.ESD IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV
3.Fast transients IEC1000-4-4. 2KV
4.Surge immunity IEC1000-4-5. 1KV line to line, 2KV line to ground
5.Conducted immunity IEC1000-4-6, 3V
6.Radiated immunity IEC1000-4-3, 3V/m
7.Magnetic field immunity EN61000-4-8, 1A/m
8.Voltage dips EN61000-4-11
9.Conducted emission EN55022A, FCC part 15-A, VCCI-A.
10. Radiated emission EN55022A, FCC part 15-A, VCCI-A.
2.5 SAFETY
1.Applicable standards: UL 60950-1, CSA 22.2 No. 60950-1,IEC 60950-1, EN 60950-1
2.Interface classification
Models with Vout 50V: Output is SELV, all communication/control interfaces: RS232/485, IEEE, Isolated Analog,LAN, Sense,
Remote Programming and Monitoring, 5V d.c. auxiliary output are SELV
Models with 60V Vout 400V: Output is Hazardous, communication/control interfaces: RS232/485, IEEE,Isolated Analog, LAN,
Remote Programing and Monitoring (pins 1-3, pins14-16), 5V d.c. auxiliary output are SELV, Sense, Remote Programming and
Monitoring (pins 8-13, pins 21-25),15V auxiliary output are Hazardous.
Models with 400V Vout 600V: Output is Hazardous, all communication/control interfaces-RS232/485, IEEE, Isolated Analog,
LAN, Sense, Remote Programming and Monitoring (all pins), 5V d.c./15V d.c. auxiliary outputs are Hazardous.
3.Withstand voltage
Vout 50V models: Input-Output/communication/control/auxiliary outputs (SELV): 4242VDC 1min,
Input-Ground: 2828VDC 1min., Output/communication/control/auxiliary outputs (SELV)-Ground: 1000VDC 1min.
60V Vout 100V models:
Input-Output/15V d.c. auxiliary output/communication/control (Hazardous): 2600VDC 1min,
Input-communication/control/5V d.c. auxiliary output (SELV): 4242VDC 1min, Output/15V d.c. auxiliary output/communication/
control (Hazardous): - communication/control/5V d.c. auxiliary output (SELV): 1900VDC 1min,Output/15V d.c. auxiliary output/
communication/control (Hazardous): -Ground: 1200VDC 1min,Input-Ground: 2828VDC 1min.
100V Vout 600V models:
Input-Output/15V d.c. auxiliary output/communication/control (Hazardous): 4000VDC 1min,
Input-communication/control/5V d.c. auxiliary output (SELV): 4242VDC 1min, Output/15V d.c. auxiliary output/communication/
control (Hazardous): -communication/control/5V d.c. auxiliary output (SELV): 3550VDC 1min, Output/15V d.c. auxiliary output/
communication/control (Hazardous): -Ground: 2670VDC 1min,
Input-Ground: 2828VDC 1min.
3.Insulation resistance More than 100Mohm at 25°C , 70% RH.
2.6 MECHANICAL CONSTRUCTION
1. Cooling Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis; Variable fan speed.
2. Dimensions (WxHxD) W: 423mm, H: 43.6mm, D: 441mm (excluding connectors, encoders, handles, etc.)
3. Weight Less than 10 kg.
4. AC Input connector (with Protective Cover)
Single Phase,230V models, Power Combicon PC 6-16/3-GF-10,16 series, with Strain relief.
3-Phase, 208V & 400V models, Power Combicon PC 6-16/4-GF-10,16 series, with Strain relief.
5.Output connectors 8V to 100V models: Bus-bars (hole Ø 10.5mm). 150V to 600V models: wire clamp connector, Phoenix P/N: FRONT-4-H-7.62
2.7 AUXILARY OUTPUTS
1. 15V Output (*8) 15V± 5%, 0.2A Max Load, Ripple & Noise 100mVp-p. referenced internally to the negative output potential.
2. 5V Output 5V± 5%, 0.2A Max Load, Ripple & Noise 100mVp-p. referenced internally to IF_COM potential.
2.8 RELIABILITY SPECS
1. Warranty 5 years.
All specifications subject to change without notice.
General Specifications Genesys™ 2.4kW