Data Sheet

3 03/08
Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and measuring conditions
Mounting information
When bending the leads, take care that the bending point is at least 3 mm apart from the face ends
of the core and that the start-of-winding areas are not subjected to any mechanical stress.
Test voltage V
test
2500 V AC, 1 min
Rated inductance L
R
Measured with LCR meter Agilent 4284A
or impedance analyzer Agilent 4294A
Measuring frequency: L
R
10 µH= 1 MHz
10 µH < L
R
1000 µH = 100 kHz
Measuring voltage: 1 V
Measuring temperature: 20 °C
Inductance tolerance ±20%
Rated temperature T
R
60 °C
Rated current I
R
Maximum permissible DC current at rated temperature
DC resistance R
typ
Measured at 20 °C, tolerance ±20%, typical values
Resonance frequency f
res
Measured with Agilent 4294A or 8753ES, 20 °C
tolerance ±30%
Solderability (lead-free) Sn95.5Ag3.8Cu0.7: (245 ±5) °C, (3 ±0.3) s
Wetting of soldering area 90%
(to IEC 60068-2-20, test Ta)
Resistance to soldering heat
(wave soldering)
(260 ±5) °C, 10 s
(to IEC 60068-2-20, test Tb)
Tensile strength of leads 30 N (to IEC 60068-2-21, test Ua)
Climatic category 55/125/56 (to IEC 60068-1)
Storage conditions Mounted: 55 °C … +125 °C
Packaged: –25 °C … +40 °C, 75% RH
Approvals EN 60938