Data Sheet

4 03/08
Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and measuring conditions
Mounting information
When bending the leads, take care that the start-of-winding areas at the face ends (protected by
glue and lacquer) are not subjected to any mechanical stress.
Rated inductance L
R
Measured with LCR meter Agilent 4284A
or impedance analyzer Agilent 4294A
Measuring frequency: L
R
10 μH= 1 MHz
10 μH < L
R
4700 μH = 100 kHz
L
R
> 4700 μH= 10 kHz
Measuring current: 1 mA
Measuring temperature: 20 °C
Q factor Q
min
Measured with precision impedance analyzer Agilent 4294A, 20 °C
Rated temperature T
R
40 °C
Rated current I
R
Maximum permissible DC current at rated temperature
Inductance decrease ΔL/L
0
10% (referred to initial value) at I
R
, 20 °C
DC resistance R
max
Measured at 20 °C
Resonance frequency f
res,min
Measured with Agilent 4294A or 8753ES, 20 °C
Solderability (lead-free) Sn95.5Ag3.8Cu0.7: (245 ±5) °C, (3 ±0.3) s
Wetting of soldering area 90%
(to IEC 60068-2-20, test Ta)
Resistance to soldering heat (260 ±5) °C, 10 s (to IEC 60068-2-20, test Tb)
Tensile strength of leads 20 N (to IEC 60068-2-21, test Ua)
Climatic category 55/125/56 (to IEC 60068-1)
Storage conditions Mounted: –55 °C … +125 °C
Packaged: –25 °C … +40 °C, 75% RH
Weight Approx. 1.1 g
B82144ARF chokes
LBC series, 5.2
12 (mm)