Place of installation
To guarantee safe, comfortable and eective use of the unit, it must be
installed in a place which complies with certain specic requirements; in
particular, before choosing where to install the unit we recommend that you
check that the following conditions are available:
- a temperature between +10°C and +25°C;
- sucient ventilation to maintain a humidity level between 20% and 70%,
when the equipment is in use;
- adequate lighting, so that the workout takes place in pleasant and relaxing
conditions;
- a safety clearance of 2 x 1 m, as shown in the illustration;
- a at, stable and vibration-free surface, and strong enough to bear the
weight of the equipment plus user.
The place of installation must comply with all the suitability requirements laid down in current legislation on this matter.
Do not expose the equipment to direct sunlight.
Do not install the equipment in areas with high humidity levels, for example close to swimming pools, whirlpools or saunas.
A dedicated power-supply circuit is recommended; this should be tted with a combined MCB/RCD with the following characteristics:
- Type C10, if the mains voltage is 200-240VAc;
- Type C16, if the mains voltage is 100-120Vac.
If it is not possible to connect the product to a dedicated power-supply circuit with the specications given, consult an electrician.