Operation Manual

MYRUN TECHNOGYM
C
D
A B
A
D
E
18
Levelling
Before use, check that the unit is level.
If one of the two feet (A) or (B) does not touch the oor, foot (A) must be
adjusted, using the spanner provided as described below.
Insert the tool supplied (C) into the hole provided and use it to prize open the
panel (D).
Loosen the lock nut (E).
Screw foot (A) in or out until both feet (A) and (B) touch the oor.
Tighten lock nut (E) after adjustment is completed.
Close panel (D).