Indoor Fireplace User Manual

42
41DVN / DVSN Direct Vent Gas Fireplace
20009999
T203
Air shutter
12/12/03 djt
IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.
NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.
Conversion Kits
Change Natural Change Propane
Model to Propane to Natural
41DVN 41DVCKP --
41DVP --
41DVDSN 20007906 --
41DVDSP --
Normal and High
Direct Vent Units - Inputs - Orifice Size - Altitude
BTU/Hr BTU/Hr Manifold Pressure Orifice 0 - 2000ft. Altitude in USA
Model Min. Input Max. Input @ Max. Orifice 0-4500ft Altitude in Canada
41DVN 20,000 30,000 3.5”w.c. #37 DMS
41DVP 19,000 27,000 10.0” w.c. #53
41DVDSN -- 30,000 3.5” w.c. #37 DMS
41DVDSP -- 27,000 10.0” w.c. #53
Air Shutter Settings
Opening
Model “A”
41DVN 1/4”
41DVP Fully Open
41DVDSN 1/4”
41DVDSP Fully Open
“A”