Indoor Fireplace User Manual

7
41DVN / DVSN Direct Vent Gas Fireplace
20009999
Mantels
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths, refer to
Figures 4a, 4b and the Mantel Chart below.
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at
any height and width around the appliance. When using
paint or lacquer, it must be heat resistant to prevent
discoloration.
Clearance to Combustibles
Top of unit to ceiling ................................. 36” (914 mm)
Front of unit to combustibles ................... 36” (914 mm)
Appliance
Top .........................................................
0” (0 mm)
Bottom .....................................................
0” (0 mm)
Side .........................................................
0” (0 mm)
Back ........................................................
0” (0 mm)
Venting
Concentric sections of DV Vent ...................
1” (25 mm)
Nonconcentric sections of DV Vent
Sides and bottom ..................................
1” (25 mm)
Top ........................................................
2” (51 mm)
Flex Vent ..................................................
7/8” (22 mm)
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01 sta
Black
Surround
Face
CFM164a
CFM170
DV Builder Front
View
O
N
M
L
K
Side of
Combustion Chamber
CFM170
Fig. 4b Combustible mantel leg minimum installation.
Mantel Mantel Leg from Side
Ref. Leg Depth Ref. of Comb. Opening
F 10” (254 mm) K 11
¹⁄₂” (292 mm)
G 8” (203 mm) L 9
¹⁄₂” (241 mm)
H 6” (152 mm) M 7
¹⁄₂” (191 mm)
I 4” (101 mm) N 5
¹⁄₂” (140 mm)
J 2” (51 mm) O 3
¹⁄₂’” (89 mm)
Y
E
A
B
C
D
F
Y
B
X
LU584-1
Locating unit
2/4/99 djt
A) Flat on wall B) Cross corner C) **Island
D) Room divider E) Flat on wall corner F) Chase installation
Y) Refer to “Clearance to Combustibles” Section
Note (Fig. 3):
** Island (C) and Room Divider (D) installation is possible as
long as the horizontal portion of the vent system (X) does not
exceed 20’ (610 cm). See details in Venting Section.
Locating Your Fireplace
Fig. 3 Locating Gas Fireplace
LU584-1
A B C
D
E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01 sta
Louvre Assembly
Top
Top of Combustion
Chamber
Bottom of Door Trim
CFM146
Fig. 4a Combustible mantel minimum installation.
Mantel Chart
Mantel Shelf Mantel from Top
Ref. or Breast Plate Ref. of Comb. Chamber
Depth
V 10” (254 mm) A 19” (483 mm)
W 8” (203 mm) B 17” (432 mm)
X 6” (152 mm) C 15” (381 mm)
Y 4” (101 mm) D 13” (330 mm)
Z 2” (51 mm) E 11” (279 mm)
Maintain Minimum
3/4” (19 mm)
Clearance to
Combustibles