tempbase. User Manual For tempbase.®-D V2 - Data Management Software tempbase.®-D v2 Data Management Software Summary Theme Page 01. Product Overview 2 02. Installation Environment 2 02.1 System Requirements 2 02.1 Operation System 2 03. Main Function 03.1 Main Interface 2 03.2 Data Query 7 03.3 Data Management 8 04. Parameter Settings 9 04.1 Parameter Settings tempmate.®-M1 9 04.2 Parameter Settings tempmate.®-S1 V2 11 05. Sensor Adjustment 13 06.
User Manual For tempbase.®-D V2 Software 01. Product Overview tempbase.®-D data management software for tempmate.®-M1 and tempmate.®-S1 V2 can program the logger, upload every recorded data to computer, systematically analyze or collect and manage the data. 02. Installation Environment 02.1 System Requirements CPU: min. PII 600 Mhz Hard disk: min. 100 Mb Memory: min. 512 Mb 02.2 Operation System Windows XP (32bit, 64bit), Windows Vista (32bit, 64bit), Win7 (32bit, 64bit), Windows8(x86/x64) 03.
User Manual For tempbase.®-D V2 Software Tool Buttons Stop by software: Stopping of the logging operation is prevented and the logger can only be stopped by tempbase.®-D software. *only for S1 V2 or M1 V1.3 Even if the tempmate.®-S1 V2 is stopped, the logger is still recording until the memory is full, or battery is low. The „Backup-Log“ can be generated by tempbase.®-D software (V2.0 or newer) and is not visible on the logger itself. *only for S1 V2 Download recorded data from tempmate.® logger.
User Manual For tempbase.®-D V2 Software Device ID tempmate.
User Manual For tempbase.®-D V2 Software Graph Stretch curve horizontally Swage curve horizontally Curve zoom in Curve zoom out Return curve to the original size Marking function in the curve Save the marking in the curve Marking event display function 5 imec Messtechnik GmbH Germany Lilienthalstraße 23 74078 Heilbronn T +49 7066.9150 230 F +49 7066.9150 233 info@imec.de www.imec.de © imec Messtechnik GmbH · V4.
User Manual For tempbase.®-D V2 Software Table Display first page data Display previous page data Display next page data Display last page data 6 imec Messtechnik GmbH Germany Lilienthalstraße 23 74078 Heilbronn T +49 7066.9150 230 F +49 7066.9150 233 info@imec.de www.imec.de © imec Messtechnik GmbH · V4.
User Manual For tempbase.®-D V2 Software 03.2 Data Query Data Base Select all loggers View the detailed information of the selected logger Display all loggers which have exceeded upper/lower limit Display all recordingings (including the normal temperature data and over temperature data) Data management function Back to home page 7 imec Messtechnik GmbH Germany Lilienthalstraße 23 74078 Heilbronn T +49 7066.9150 230 F +49 7066.9150 233 info@imec.de www.imec.de © imec Messtechnik GmbH · V4.
User Manual For tempbase.®-D V2 Software 03.3 Data Management Backup or Restore Data backup (save data in the format of ELT) Data restore (Restore ELT file and read it by software) 8 imec Messtechnik GmbH Germany Lilienthalstraße 23 74078 Heilbronn T +49 7066.9150 230 F +49 7066.9150 233 info@imec.de www.imec.de © imec Messtechnik GmbH · V4.
User Manual For tempbase.®-D V2 Software 04. Parameter Setting 4.1 tempmate.®-M1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 1. Serial Number Shows the serial number of the connected device 2. Internal ID Internal ID can be saved to the tempmate.®-M1 3. Log Interval Adjust the time between the measuring points 4. Log Cycle Calculates the maximum runtime until the storage is full (battery life excluded!) 5.
User Manual For tempbase.®-D V2 Software 13. Record Mode Select “Stop when full” or “Ring Buffer” 14. Stop Mode Select “Stop by Button” or “Stop by Software“ 15. Time Zone Change the time zone (factory setting is UTC +00:00) 16. Battery Shows the battery status of the current device 17. Display Time Setup the time the display is active 18. Probe Mode Choose whether internal or external sensor should be used 19. Multiple Start/Stop Enable • tempmate.
User Manual For tempbase.®-D V2 Software 4.2 tempmate.®-S1 V2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 1. Serial Number Shows the serial number of the connected device 2. Internal ID Internal ID can be saved to the tempmate.®-S1 V2 3. Log Interval Adjust the time between the measuring points 4. Log Cycle Calculates the maximum runtime until the storage is full (battery life excluded!) 5. Temporary Report Automatic report generation without stopping the logger 6.
User Manual For tempbase.®-D V2 Software 13. Record Mode “Stop when full” is mandatory for tempmate.®-S1 V2 14. Stop Mode Select “Stop by Button” or “Stop by Software“ 15. Time Zone Change the time zone (factory setting is UTC +00:00) 16. Battery Shows the battery status of the current device 17.
User Manual For tempbase.®-D V2 Software 05. 5. Sensor Adjustment (only for tempmate.®-M1) 13 imec Messtechnik GmbH Germany Lilienthalstraße 23 74078 Heilbronn T +49 7066.9150 230 F +49 7066.9150 233 info@imec.de www.imec.de © imec Messtechnik GmbH · V4.0-05/2016-EN · Technical Changes and Errors excepted Temperature adjustment range: for Celsius ±5.
User Manual For tempbase.®-D V2 Software 06. Export Data Export data in the format of EXCEL Export data in the format of PDF Export data in the format of ELT 14 imec Messtechnik GmbH Germany Lilienthalstraße 23 74078 Heilbronn T +49 7066.9150 230 F +49 7066.9150 233 info@imec.de www.imec.de © imec Messtechnik GmbH · V4.