Installation Manual

Greenlee Textron / Subsidiary of Textron Inc.
7
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Fiber Optic Installation Kit
f) Using a wipe, wick away the excess adhesive
that surrounds the protruding fiber.
Note: For distribution style cable that does not
include a crimp sleeve, follow the same
procedure except for c and d. Instead,
hold the connector and cable in place for
approximately 10 seconds before
securing the strain relief boot.
10. Lightly score the outside edge of the fiber near the
base of the protruding fiber with the hand scribe,
as shown. Being very careful of the fiber debris, use
a thumb and index finger to gently lift the excess
fiber off of the connector. If the fiber does not lift of
easily, repeat this step. Dispose of fiber end in the
container provided.
Procedure (contd)
11. Perform an air polish by holding the connector and
gently brushing the non-shiny side of the 5 µm
polishing paper in a circular motion against the
ferrule endface, as shown. Perform ten to twenty
circles of the polishing motion.
12. Place the polishing pad onto a flat surface. Place
the 5 µm polishing paper, shiny side down, onto the
polishing pad. With the connector in the polishing
tool, polish the end of the fiber in a traveling figure-8
motion. Begin with very light pressure and increase
pressure as it begins to wear.