Datasheet

testo Saveris
testo Saveris router
V 1.0
testo Saveris converter
V 1.0
-20 to +50 °C
· for testo Saveris Base
Firmware Version V 1.X
· for testo Saveris Base
Firmware Version V 2.X
· for testo Saveris Base
Firmware Version V 1.X
· only for wireless probes
Firmware Version 1.X
Approx. 85 x 100 x 38 mm
Plastic
Approx. 180 g Approx. 190 g
-40 to +60 °C
IP54
Radio
max. 5 max. 15
6.3 V DC mains unit; alternatively via 24
V AC/DC plug-in/screw terminals, power
consumption < 0.5 W
6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals,
PoE, power consumption < 2 W
Power supply
Connectable radio
probe
Application
Dimensions
Operating temperature
Housing material
Weight
Storage temperature
Protection class
Interfaces
testo Saveris Router
V 2.0
testo Saveris
Extender
testo Saveris Converter
V 2.0
· for testo Saveris Base
Firmware Version V 2.X
· only for wireless probes
with Firmware Version 2.X
· for all testo Saveris
Base Firmware versions
· only for wireless probes
with Firmware Version
2.X
Radio, Ethernet
max. 15 m in stationary operation
max. 100 m in mobile operation
no -
included
Router cascading
Wall bracket
yes --
Router, Converter and Extender
0572 0119testo Saveris Router V 1.0, 868 MHz, radio transmission medium
0572 0219testo Saveris Router V 2.0, 868 MHz, radio transmission medium
0572 0118testo Saveris Converter V 1.0, 868 MHz, converts the radio transmission medium to Ethernet
0572 0218testo Saveris Converter V 2.0, 868 MHz, converts the radio transmission medium to Ethernet
0572 0217testo Saveris Extender 868 MHz, converts the radio transmission medium to Ethernet
No mains units are contained in this ordering data.
Part no.
Technical data