Datasheet

testo Saveris
Measuring range
Accuracy
-35 to +50 °C
±0.4 °C (-25 to +50 °C)
±0.8 °C (remaining range)
Measuring range
(Instrument)
Accuracy
(Instrument)
Resolution (Instrument)
Dimensions (housing):
Operating temperature
Probe type
Probe type
NTC
Weight
Storage temperature
Measuring rate
Protection class IP68
Conformity with standards
Radio frequency
NTC via mini-DIN socket,
door contact connection
cable included in delivery
(1.80 m)
Connection
Battery life
(Type: 4 AA batteries)
Display (optional)
Transmission distance
-35 to +50 °C
±0.4 °C (-25 to +50 °C)
±0.8 °C (remaining range)
NTC
0.1 °C
-50 to +150 °C
±0.2 °C (-25 to +70 °C)
±0.4 °C (remaining range)
NTC
2 TCs via TC socket, max.
difference in potential 2 V
-200 to +400 °C
TC type T
0.1 °C / TC type S 1 °C
-195 to +1350 °C
±0.5 °C or 0.5% of m.v.
TC type K
0 to +1760 °C
TC type S
-100 to +750 °C
TC type J
IP54
1 Pt100 via mini-DIN socket
0.01 °C
-200 to +600 °C
at +25 °C
±0.1 °C (0 to +60 °C)
±0.2 °C (-100 to +200 °C)
±0.5 °C (remaining range)
Pt100
IP68
Housing material
-35 to +50 °C
Approx. 240 g
Standard 15 min, 1 min to 24 h can be set
Memory
6,000 measurement values per channel
-40 to +55 °C (incl. batteries)
DIN EN 12830
Battery life at +25 °C, 3 years; for freezer applications, 3 years with L91 Photo lithium Energizer batteries
-20 to +50 °C
LCD, 2 lines; 7-segment with symbols
approx. 300 m without obstruction at a frequency of 868 MHz
Plastic
868 MHz
Wall bracket
included
Radio probes
0.1 °CResolution 0.1 °C
80 x 85 x 38 mm
testo Saveris T1 testo Saveris T2 testo Saveris T3 testo Saveris Pt
Internal sensorExternal probe
Technical data
*The testo Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of testo Saveris wireless probes into systems with Base Firmware V 1.X . For more information please
contact our customer hotline or your Testo partner.
The alkali manganese batteries AA (0515 0414) are included in these ordering data (Analog Coupler excluded). testo Saveris probes are delivered with a calibration protocol of the factory
adjustment data. Calibration certificates must be ordered separately.
Version without display
0572 1210*testo Saveris T1 Radio probe with internal NTC, radio frequency 868 MHz, without display
0572 1211*
testo Saveris T2 Radio probe with external probe connection and internal NTC, door contact, radio frequency 868 MHz, without display
0572 9212*testo Saveris T3 2-channel radio probe with 2 external TC probe connections (choice of TC characteristics), radio
frequency 868 MHz, without display
0572 7211*testo Saveris Pt Radio probe with 1 external Pt100 probe connection, radio frequency 868 MHz, without display
Version with display
0572 1220*testo Saveris T1 D Radio probe with internal NTC, radio frequency 868 MHz, with display
0572 1221*testo Saveris T2 D Radio probe with external probe connection and internal NTC, radio frequency 868 MHz, with display
0572 9222*testo Saveris T3 D 2-channel radio probe with 2 external TC probe connections (choice of TC characteristics),
radio frequency 868 MHz, with display
0572 7221*testo Saveris Pt D Radio probe with 1 external Pt100 probe connection, radio frequency 868 MHz, with display
Part no.