Installation Guide

Page. 14
1. To change to horizontal discharge, move the
discharge cover to the top of the hood. Use a 3/8'' nut
driver to remove the (4) 3/8'' hex nuts from the plate.
Assembly of the Transition
Hoods are supplied with a 10" (254 mm) round transition.
A locally supplied transition is required for other sizes.
The supplied transition mounts to the top or rear of the
hood, depending on the discharge direction.
A minimum height clearance of 8-3/8'' (212 mm) is needed
above the hood for transition mounting.
2. Depending on direction of discharge, align mounting
holes at base of transition with the mounting holes of
the ½'' (13 mm) flange located at the top or rear of
the hood.
3. Fasten transition to hood using four (4) 1/4'' (6 mm)
sheet metal screws included with hood.
Note: Screws must not hinder damper operation.
4. Seal connection between transition and hood with
aluminum tape. DO NOT use duct tape. Ensure that
the connection is completely sealed.
5. Remove tape holding damper closed.
Wall Mount Installation
Wood Hanging Bracket
1. The installation height ranges from a minimum height
of 30'' (762 mm) to a maximum height of 40''
(1,016 mm); however, it is necessary to follow the
cooking appliance manufacturer’s installation
instructions for proper hood height. (See “Clearances
and requirements” on page 8.)
2. After the hood installation height has been
determined, draw a horizontal line at a distance above
the cooktop equal to the recommended hood
installation height plus 16½'' (419 mm). This line is the
mounting location of the wood support bracket
shipped with the hood.
26"
(669)
26"
(669)
18"
(457)
18"
(457)
8
"
(212)
8"
(212)
inches (mm)
*Follow cooking appliance manufacturer’s recommendations.
*30" (762) –
40" (1016)
16½"
(419)
16½"
(419)