Installation Instructions
Table Of Contents
- Table of
- Safety
- Safety
- Installation instructions
- Planning information
- Ventilation requirements
- Installation clearances
- Unpacking and setting the rangetop
- Gas requirements and hookup
- Electrical requirements and connection for gas units
- Low backguard installation (optional)
- Burner test
- Final checklist
- Renseignements de planification
- Exigences en matière de ventilation
- Espaces libres pour l’installation
- Déballage et mise en place
- Exigences pour l'alimentation du gaz et raccordement
- Exigences électrique et branchement pour les unité au gaz
- Installation de la plaque de protection basse (optionnel)
- Test de brûleurs
- Liste de vérification
- 9 INSTRUCCIONES IMPORTANTES DE SEGURIDAD LEA TODAS LAS INSTRUCCIONES ANTES DE CONTINUAR
- Información de planificación
- Requisitos de ventilación
- Espacios libres para la instalación
- Mover y anclaje la parrilla
- Requerimientos de gas y conexiones
- Requerimientos eléctricos y conexión para unidades de gas
- Instalación de la consola trasera de protección (opcional)
- Probar el quemador
- Lista de chequeo final
- Blank Page
- Blank Page
Page. 11
Gas inlet location
A manual valve must be installed external to the
appliance, in an accessible location from the front, for the
purpose of shutting off the gas supply.
Unpacking and setting the
rangetop
9 CAUTION
Proper equipment and adequate manpower
must be used in moving the appliance to avoid
damage and/or personal injury. The unit is heavy
and should be handled accordingly.
Hidden surfaces may have sharp edges. Use
caution when handling the appliance. Failure to
do so may result in property damage or personal
injury.
Removing the rangetop from the pallet
1. Remove the outer carton and packing material from
the shipping base. Ensure that you have
all rangetop
components before proceeding.
2. Remove the cooking grates, griddle plate (if
applicable), and burner caps
to reduce the rangetop’s
weight.
Side view of rangetop
Projecting from cabinet front
Installation of rangetop above Thermador warming drawers
Cabinet face for installation with
projecting control panel.
Cabinet face for installation
with flush control panel.
7
5
/
8
"
(194)
7
5
/
8
"
(194)
7
5
/
8
"
(194)
7
/
8
"
(22)
7
/
8
"
(22)
7
/
8
"
(22)
26¾" (680)26¾" (680)26¾" (680)
22½" (573)22½" (573)22½" (573)
½" (12.7)
side flange
½" (12.7)
side flange
½" (12.7)
side flange
inches (mm)
1½"
(38)
Front projects outward 13/16" (20) as
shown from standard 24" deep base.
Notch DepthNotch DepthNotch Depth
111111
//
161616
""
(18)(18)(18)
13
/
16
"
(20)
inches (mm)
Plywood support
Install additional
wood support along
front edge of cutout
2¾" (70)
min. between
cutouts
7
5
/
8
"
(194)
7
5
/
8
"
(194)
7
5
/
8
"
(194)
inches (mm)
Gas Inlet Location 30'' 36'' 48''
From left side to
centerline of gas inlet
6-3/8''
(152 mm)
11" (267 mm)
From rear to centerline of
gas inlet
2¼'' (54 mm)
¾" (19) ex line¾" (19) ex line¾" (19) ex line
½" (12.7) NPT½" (12.7) NPT½" (12.7) NPT
inches (mm)