Installation Instructions

Installation Instructions English | 14 |
ATTENTION – PROPERTY DAMAGE
Contact a qualified installer or contractor to determine
the proper method for drilling holes through the wall or
floor material (such as ceramic tile, hardwood, etc.)
DO NOT slide the range across an unprotected floor.
Failure to follow these instructions may result in
damage to wall or floor coverings.
Important Installation Information
Hardware provided is for mounting through standard
thickness wood studs. Installers are responsible to
provide hardware for other types of mounting
situations.
The anti-tip bracket may be attached to a solid wood
surface having a minimum wall thickness of ¾''
(19 mm).
The thickness of the wall or floor may require use of
longer screws, available at your local hardware store.
In all cases,
at least two (2) of the bracket mounting
screws must be fastened to solid wood surface.
Use appropriate anchors when fastening the mounting
bracket to any material other than hard-wood or metal.
Hole Location Preparation
For walls, wall studs, or floors composed of solid wood
or metal, drill 1/8'' (3 mm) pilot holes.
For walls or floors composed of drywall, sheet-rock or
other soft materials, drill 3/16'' (5 mm) holes to a
minimum depth of 1¾'' (45 mm), then tap plastic
anchors into each of the holes using a hammer.
For walls or floors composed of concrete or concrete
block, drill 3/16'' (5 mm) holes to a minimum depth of
1¾'' (45 mm), then tap concrete anchors into each of
the holes using a hammer.
For walls or floors having ceramic tile covering, drill
3/16'' (5 mm) holes through the tile only, then drill into
the material behind the tile as indicated immediately
above.
Mounting the Anti-Tip Bracket
1. Insert the 2¼'' (57 mm) anti-tip bolt into the bottom of
the hole vacated by the center, rear pallet bolt
(Figure 8).
2. Finger tighten the anti-tip bolt. Allow 1ǫ" – 1Ǭ" (41 –
48 mm) clearance for the anti-tip bolt head to slide into
the anti-tip bracket once the range is pushed into place
(Figure 8).
3. Place the bracket on the floor in the position shown in
Figure 9. Secure to floor and wall stud using the (4)
1½'' (38 mm) Phillips head screws provided.
4. If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
Figure 8: Anti-tip Bolt
Figure 9: Placement of Anti-Tip Bracket
1⅝" – 1⅞"
(41 – 48)
1⅝" – 1⅞"
(41 – 48)
1⅝" – 1⅞"
(41 – 48)
inches (mm)
34"
(864)
34"
(864)
34"
(864)
21¾"
(552)
21¾"
(552)
21¾"
(552)
inches (mm)