Fault Possible cause Remedial action
The Ice Maker does not make
enough ice or the ice is
deformed.
The appliance or Ice Maker has only
just been switched On.
Approximately 24 hours is needed until ice
production starts.
A lot of ice has been taken. Approximately 24 hours is needed until
the Ice Cube Container is filled again.
Low water pressure. Connect the appliance to the stipulated
water pressure only (see chapter
“Connecting Appliance”, section “Water
Connection”).
The Filter Cartridge is blocked or
needs to be replaced.
Exchange the Filter Cartridge.
Temperature in the Freezer
Compartment is too warm.
Set temperature slightly colder
in the Freezer Compartment.
The Ice Maker does not make
any ice.
The Ice Maker is switched Off. Switch the Ice Maker On at the control
panel.
The appliance is not supplied with
water.
Contact the installer or the Water Supply
company.
Water Supply has kinks. Turn Off the Water Supply at the Shut Off
Tap. Smoothen out the kinks, exchange
where necessary.
Low Water Pressure. Connect the appliance to the stipulated
water pressure only (see chapter
“Connecting Appliance”, section “Water
Connection”).
Temperature in the freezer space is
too warm.
Check Freezer Compartment temperature
and, if required, set slightly colder.
Ice Cube Container is not properly
inserted.
Check the position, re-insert where
necessary.
Incorrect Shut Off Tap installed. Incorrect Shut Off Taps can cause low water
pressure and damage to the appliance.
The Light at the Ice and Water
Dispenser does not work.
The Light is switched Off. Press the Button at the Ice and Water
Dispenser Control Panel.
The Light is defective. See chapter “Light (LED)“.
Ice forms in the inflow hose
to the Ice Maker.
Low Water Pressure. Connect the appliance to the stipulated
water pressure only (see chapter
“Connecting Appliance”, section “Water
Connection”).
Shut Off Tap incorrectly opened. Open Shut Off Tap fully.
Water runs from the appliance. The Water Connection Hose is not
properly sealed.
Replace the hose with a manufacturer’s
original part.
Incorrect Shut Off Tap installed. Incorrect taps can cause low water pressure
and damage to the appliance.
The water pressure is less than
usual.
Low Water Pressure. Connect the appliance to the stipulated
water pressure only (see chapter
“Connecting Appliance”, section “Water
Connection”).
Shut Off Tap incorrectly opened. Open Shut Off Tap fully and check for leaks.
Check the minimum through flow.
Incorrect Shut Off Tap installed. Incorrect taps can cause low water pressure
and damage to the appliance.
Water Supply has kinks. Turn Off the Water Supply at the Shut Off
Tap. Smoothen out the kinks, exchange
where necessary.
The Filter Cartridge is blocked or
needs to be replaced.
Exchanging the Filter Cartridge.