Installation guide

16. Attaching the toe kick pane[
The maximum height of the toe kick panel is 4" from
the top of the floor. Do not cover ventilation slots in
the base panel. Risk of damage to the appliance.
Q If required, cut the toe kick panel to the required
length.
Q Remove the cap from the appliance connection (_!}.
Q Bend the water pipe according to the location of the
connection on the appliance _2}.
Q Push the union nut and seal onto the water pipe.
Q Push the end of the water pipe into the appliance
connection and screw on the union nut _3}.
Tighten hand-tight.
Q Using the open-ended wrench, tighten the union
nut. Do not overturn[
Q
Open the shut-off valve and main water tap.
Check the connection on the shut-off valve and
on the appliance for leaks.
Q Attach the base panel to the appliance.
[
Q
Q
Remove the protective film from the adhesive pads
on the Velcro.
Fit the toe kick panel to the base panel and press
firmly into place.
29