Installation instructions

8
Connecting the power
, WARNING
Avoid the risk of an electric shock!
Insert into a grounded 3-phase socket.
Never remove grounding phase. Do not use any
adapters. Do not use any extension cables.
Non-compliance with these instructions may
result in death, fire or an electric shock.
Improper connection of the protective
conductor may result in an electric shock. If you
are in doubt whether the appliance has been
grounded properly, have the appliance tested
by a qualified electrician or service technician.
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with protection class I.
Connect the appliance to 115 V/60 Hz alternating
current via a correctly installed socket with protective
conductor. The socket must be fused with a 10 to 16 A
fuse.
The appliance comes with a UL registered 3-wire power
cord. The appliance requires a 3-pole socket. Please
observe the following table with regard to this:
(*) incl. IceMaker
Check on the rating plate whether the indicated voltage
and current type correspond with the values of your
power supply. The location of the rating plate can be
found in the chapter entitled Customer service.
, WARNING
Never connect the appliance to electronic energy
saver plugs. Our appliances can be used with
mains and sine-controlled inverters. Mains-
controlled inverters are used for photovoltaic
systems which are connected directly to the
national grid. Sine-controlled inverters must be
used for isolated applications (e.g. on ships or in
mountain lodges) which are not connected
directly to the national grid.
Connecting the water
, CAUTION
Only connect the appliance to drinking water!
The water may be connected only by a competent fitter
according to the local regulations of the appropriate
water supply company.
A cold water connection is necessary for operating the
automatic ice maker. The water pressure must be
between 25 and 120 p.s.i. (1,72 and 8,25 bar).
The installation must correspond to the local plumbing
regulations.
A separate shut-off valve should be installed in the cold-
water inflow. The shut-off valve should not be located
behind the appliance. It is recommended that you mount
the shut-off valve directly next to the appliance or at
another place which is easily accessible. When installing
the water connection, pay attention to the permissible
installation area for the water mains.
For connection to the drinking water mains use only
water pipes which are suitable for drinking water.
Observe national regulations and the connection
conditions of the local water supply companies.
When installing the water connection, observe the
permitted installation areas for the pipe. For the
permitted installation areas and dimensions see
“Dimensions of the installation niche”.
Maximum outer diameter of the water pipe
(without fittings):
3
/
8
" (9.5 mm).
Appliance Maximal load at one time
Refrigerator 24" 2.0 Ampere
Refrigerator 30" 2.0 Ampere
Freezer 18" (*) 3.5 Ampere
Freezer 24" (*) 4.0 Ampere
Freezer 30" (*) 4.5 Ampere
Wine unit 18" 2.0 Ampere
Wine unit 24" 2.0 Ampere