Installation Guide

Page 15
Optional: Electrical panel can be mounted in
a remote location.
Example: There is a drawer at the bottom of the cabinet, in front of the
downdraft. This may require the electrical panel to be mounted in an
adjacent cabinet. If blower discharge is down, electrical panel must be
relocated.
1. Remove (4) no. 8-32 hex nuts and electrical panel. 5-ft. (1.5 m)
extension cables (purchase separately) may be needed to mount
electrical panel in a remote location. Do not use more than 2 extension
cables (EXTNCE5). Do not mount with electrical panel slots facing
downward.
2. Installation of a remotely located electrical panel may be completed
after connecting the ductwork and installing the blower. Install
electrical panel according to local codes.
INSTALLATION
No. 8-32
HEX NUTS
Based on blower and ducting option selected,
go to the relevent section:
A - Installation using fl exible blower
attached to downdraft
B - Installation using fl exible or remote
blower - mounted in a remote location -
ducting through front panel opening
C - Installation using inline or remote blower
- mounted in a remote location - ducting
through left, right, below or rear
A - Installation using fl exible blower
attached to downdraft
(Purchase Model VTD600P Flexible Blower separately.)
1. Remove hex nuts to remove front panel cover.
2. Determine whether  ex blower will discharge to the left, right,
ordown.
3. If blower discharge is down, remove (4) no. 8-32 hex nuts and
electricalpanel.
4. Place blower over studs around front panel opening.
5. Tighten hex nuts to secure blower in place.
BLOWER
SUPPORT LEGS
(4) BOLTS
6. Remove bolts from  ex blower housing. Attach blower support legs
to  ex blower housing with these (4) bolts. Do not tighten bolts at
this time.