Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Liquidtight Flexible Metal Conduit Fittings
A-116
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
Ground Wire
Max. over Ribs
90º Angle Ground Fittings
Malleable iron tapered hub threads.
Ground Wire
Max.
over Ribs
45º Angle Ground Fittings
Malleable iron, tapered hub threads.
C
A
B
Straight Ground Fittings
Malleable iron, tapered
hub threads.
Malleable iron with tapered hub threads!
Grounding Fittings — Straight
*
, 45° Angle and 90° Angle
Revolver
®
Ground Ring
CAT. NO.
GROUND
STEEL STEEL ALUMINUM CONDUIT DIMENSIONS (IN.) WIRE
INSULATED NON-INSULATED NON-INSULATED SIZE A B C (AWG)
Straight Grounding Fittings
5331GR** 5231GR* 5231 ALGR*
3
⁄8"1
5
⁄32 1
1
⁄2
9
⁄16 14-8
5332GR* 5232GR* 5232ALGR*
1
⁄2"1
3
⁄8 1
9
⁄16
9
⁄16 14-8
5333GR* 5233GR* 5233ALGR*
3
⁄4"1
21
⁄32 1
5
⁄8
9
⁄16 14-4
5334GR* 5234GR* 5234ALGR* 1" 1
7
⁄8 2
1
⁄16
3
⁄4 14-4
5335GR 5235GR — 1
1
⁄4"2
1
⁄4 2
1
⁄2
13
⁄16 8-1/0
5336GR 5236GR — 1
1
⁄2"3
1
⁄4 2
11
⁄16
13
⁄16 4-2/0
5337GR 5237GR — 2" 3
13
⁄16 3
1
⁄16
7
⁄8 4-2/0
5338GR 5238GR — 2
1
⁄2"4
7
⁄16 4
1
⁄8 1 2-4/0
5339GR 5239GR — 3" 5
3
⁄16 4
1
⁄4 1 2-4/0
5340GR 5240GR — 4" 6
1
⁄8 4
1
⁄2 1
1
⁄8 2-4/0
5385GR 5285GR — 5" 8
9
⁄16 71
7
⁄8 2-4/0
5386GR — — 6" 8
17
⁄32 8
1
⁄2 2 2-4/0
90° Angle Grounding Fittings
5351GR** 5251GR** 5251ALGR*
3
⁄8"1
5
⁄32 1
1
⁄4
9
⁄16 14-8
5352GR* 5252GR* 5252ALGR*
1
⁄2"1
3
⁄8 1
7
⁄16
9
⁄16 14-8
5353GR* 5253GR* 5253ALGR*
3
⁄4"1
21
⁄32 1
13
⁄16
9
⁄16 14-4
5354GR* 5254GR* 5254ALGR* 1" 1
7
⁄8 2
1
⁄16
3
⁄4 14-4
5355GR* 5255GR — 1
1
⁄4"2
1
⁄4 2
1
⁄2
13
⁄16 8-1/0
5356GR 5256GR — 1
1
⁄2"3
1
⁄4 2
15
⁄16
13
⁄16 4-2/0
5357GR 5257GR — 2" 3
13
⁄1 3
7
⁄16
7
⁄8 4-2/0
5358GR 5258GR — 2
1
⁄2"4
7
⁄16 8
7
⁄8 1 2-4/0
5359GR 5259GR — 3" 5
3
⁄16 10
1
⁄4 1 2-4/0
5360GR 5260GR — 4" 6
1
⁄8 12
5
⁄8 1
1
⁄8 2-4/0
GROUND
CAT. NO.
CONDUIT DIMENSIONS (IN.) WIRE
INSULATED NON-INSULATED SIZE A B C (AWG)
45° Angle Grounding Fittings
5341GR** 5241GR**
3
⁄8"1
5
⁄32 1
9
⁄16
9
⁄16 14-8
5342GR* 5242GR*
1
⁄2"1
3
⁄8 1
7
⁄8
9
⁄16 14-8
5343GR* 5243GR*
3
⁄4"1
21
⁄32 2
1
⁄8
9
⁄16 14-4
5344GR* 5244GR* 1" 1
7
⁄8 2
1
⁄4
3
⁄4 14-4
5345GR 5245GR 1
1
⁄4"2
1
⁄4 2
3
⁄4
13
⁄16 8-1/0
5346GR 5246GR 1
1
⁄2"3
1
⁄4 3
3
⁄8
13
⁄16 4-2/0
5347GR 5247GR 2" 3
13
⁄16 3
7
⁄8
7
⁄8 4-2/0
5348GR 5248GR 2
1
⁄2"4
7
⁄16 4
1
⁄4 1 2-4/0
5349GR 5249GR 3" 5
3
⁄16 4
1
⁄4 1 2-4/0
5350GR 5250GR 4" 6
1
⁄8 4
5
⁄8 1
1
⁄8 2-4/0
**
3
⁄
8
" conduit fittings have
1
⁄
2
" trade size hub. With safe-edge ground cone (through 4") and double bevel sealing ring (through 2").
UL Listed liquidtight; and CSA Certified watertight. Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2;
Class III, Div. 1 and 2, where general purpose equipment is specifically permitted per NEC Section 500-2(a). Available with
DURA-PLATE
®
Finish. UL File No. E 3060 CSA File No. 638
*NOTE:
3
⁄
8
"–1" fittings include Revolver
®
grounding device. For sizes 1
1
⁄
4
" and up, fittings are supplied with a copper mechanical lug.