Operating Guide

Instructions for Converting Range to Operate on Liquefied Petroleum Gas
2.Convert Top Burner for LP/ Propane Gas
Save the natural gas orifices removed from the appliance for possible future conversions to natural gas. You
should rely on the following process when converting unit back to Nature gas. Take extra care when handling
orifice parts, making sure the orifice is not
a. Remove top grates, burner caps and inner burner rings.
b. Lift off outer burner heads and burner bases.
c. Remove the factory installed natural gas orifices from the center of the orifice holders using a 7mm nut driver
Remember to keep the original natural gas orifices for future conversions back to natural gas.
“IMPORTANT” to identify their markings.
c.1. Replace the 18000BTU burner orifice in each with orifice size 1.24 mm.
c.2 Replace the 12000BTU burner orifice in each with orifice size 1.00 mm. Please remember not to over tighten
the orifice and keep the orifice clean.
c.3 Replace the 9000BTU burner orifice in each with orifice size 0.88 mm. Please remember not to over tighten
the orifice and keep the orifice clean.
Put the burner flame ring back to the main burner bases. Put back the inner burner rings, burner caps and grates.