Product Manual

21
cleanup
PowrBeast
6.4 CLEANING THE FILTER SCREEN
i
A clean lter screen always guarantees maximum
feed quantity, constant spraying pressure and
problem-free functioning of the unit.
SUBMERSIBLE SUCTION SYSTEM
1. The lter screen will clog and must be cleaned at least
once a day.
2. Remove the retaining ring (Fig. 13, item 1) from the foot
valve housing (2).
3. Remove the inlet screen (3) from the foot valve housing
(2).
4. Clean thoroughly with the appropriate solvent.
2
3
1
STANDARD SUCTION SYSTEM
1. Screw o the lter (Fig. 14) from suction tube.
2. Clean or replace the lter.
Carry out cleaning with a hard brush and an appropriate
cleaning agent.
6.5 CLEANING AIRLESS SPRAY GUN
i
Clean the spray gun after each use.
1. Rinse airless spray gun with an appropriate cleaning agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the airless spray gun.
INTAKE FILTER IN AIRLESS SPRAY GUN FIG. 15
1. Unclip the top of the trigger guard (1) from the gun head.
2. Using the bottom of the trigger guard as a wrench, loosen
and remove the handle assembly (2) from the gun head.
3. Pull the old lter (3) out of the gun head. Clean or replace.
4. Slide the new lter, tapered end rst, into the gun head.
5. Thread the handle assembly into the gun head. Tighten
with the trigger wrench.
6. Snap the trigger guard back onto the gun head.
1
2
3