maintenance
PowrBeast
INSPECTION FIG. 17
Inspect all parts of the lter assembly before reassembly.
1. Inspect the ball inside the lter element. If the ball has
pressure cuts or scratches, replace the lter element.
a. If the ball is cut, remove the PTFE o-ring (5) using an
o-ring pick and remove the carbide seat (6).
b. Check the seat for nicks or grooves. If the seat is
damaged, replace.
i
Removal of the PTFE o-ring will damage the
o-ring and require replacement.
2. Remove the spring (2) from the spring guide on the lter
cap.
a. Measure the length of the spring uncompressed. If it
measures less than 3/4” from end to end, replace.
b. Push the spring back onto the spring guide until it
“snaps” back into position.
3. Inspect the two PTFE gaskets (7,8) and the PTFE o-ring (5)
for deformity, nicks, or cuts. Replace, if needed.
i
The PTFE gaskets, PTFE o-ring, and spring are
packaged in Filter Service Kit P/N 930-050.
REASSEMBLY FIG. 17
After cleaning and inspecting all parts, reassemble the lter.
1. Place the carbide seat (6) into the lter body (4). Make sure
the beveled side of the seat is facing up.
2. Place the PTFE o-ring (5) into the groove on the outer
diameter of the carbide seat (6).
3. Place the lter element with ball (3) into the lter body (4).
i
The top and bottom of the lter element with
ball are identical.
4. Push the spring (2) back onto the spring guide of the lter
cap (1) until it “snaps” back into position, if not already
done.
5. Place the thin PTFE gasket (8) onto the step at the top of
the lter body (4).
6. Place the thick PTFE gasket (7) onto the top of the thin
gasket (8).
7. Tighten the lter cap assembly (1) onto the lter body (4).
7.4 MAINTAINING THE HYDRAULIC SYSTEM
At
tention
Use of Titan’s Coolo™ Hydraulic Fluid is
mandatory in the PowrBeast hydraulic system.
Do not use any other hydraulic uid. Use of any
other hydraulic uid may seriously damage the
hydraulic system and will void the warranty.
1. Check the hydraulic uid daily. The hydraulic uid level
should be touching the bottom of the dipstick (1). If it is
dry, add only Titan Coolo™ Hydraulic Fluid (P/N 430-361).
Never add or change hydraulic uid except in a clean,
dust-free area. Contamination of the hydraulic uid will
shorten hydraulic pump life and may void warranty.
i
Make sure the unit is on a at, level surface when
checking the hydraulic uid level.
2
1
3