INSPECTION FIG. 17
Inspect all parts of the lter assembly before reassembly.
1. Inspect the ball inside the lter element. If the ball has
pressure cuts or scratches, replace the lter element.
a. If the ball is cut, remove the PTFE o-ring (5) using an
o-ring pick and remove the carbide seat (6).
b. Check the seat for nicks or grooves. If the seat is
damaged, replace.
i
Removal of the PTFE o-ring will damage the
o-ring and require replacement.
2. Remove the spring (2) from the spring guide on the lter
cap.
a. Measure the length of the spring uncompressed. If it
measures less than 3/4” from end to end, replace.
b. Push the spring back onto the spring guide until it
“snaps” back into position.
3. Inspect the two PTFE gaskets (7,8) and the PTFE o-ring (5)
for deformity, nicks, or cuts. Replace, if needed.
i
The PTFE gaskets, PTFE o-ring, and spring are
packaged in Filter Service Kit P/N 930-050.
REASSEMBLY FIG. 17
After cleaning and inspecting all parts, reassemble the lter.
1. Place the carbide seat (6) into the lter body (4). Make sure
the beveled side of the seat is facing up.
2. Place the PTFE o-ring (5) into the groove on the outer
diameter of the carbide seat (6).
3. Place the lter element with ball (3) into the lter body (4).
i
The top and bottom of the lter element with
ball are identical.
4. Push the spring (2) back onto the spring guide of the lter
cap (1) until it “snaps” back into position, if not already
done.
5. Place the thin PTFE gasket (8) onto the step at the top of
the lter body (4).
6. Place the thick PTFE gasket (7) onto the top of the thin
gasket (8).
7. Tighten the lter cap assembly (1) onto the lter body (4).
7.4 MAINTAINING THE HYDRAULIC SYSTEM
At
tention
Use of Titan’s Coolo™ Hydraulic Fluid is
mandatory in the PowrBeast hydraulic system.
Do not use any other hydraulic uid. Use of any
other hydraulic uid may seriously damage the
hydraulic system and will void the warranty.
1. Check the hydraulic uid daily. The hydraulic uid level
should be touching the bottom of the dipstick (1). If it is
dry, add only Titan Coolo™ Hydraulic Fluid (P/N 430-361).
Never add or change hydraulic uid except in a clean,
dust-free area. Contamination of the hydraulic uid will
shorten hydraulic pump life and may void warranty.
i
Make sure the unit is on a at, level surface when
checking the hydraulic uid level.
2
1
3