Preparing a New Sprayer
If this sprayer is new, it is shipped with test uid in the uid
section to prevent corrosion during shipment and storage. This
uid must be thoroughly cleaned out of the system with mineral
spirits before you begin spraying.
IMPORTANT: Always keep the trigger lock on the spray gun
in the locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure
control knob to the “MIN” setting.
Rapid Clean
RAPID
CLEAN
Pump OFF
Pressure
Control Knob
Pressure
Indicator
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn on the sprayer by moving the ON/OFF switch to the
ON position.
6. Allow the sprayer to run for 15–30 seconds to ush the
test uid out through the return hose and into the waste
container.
7. Turn off the sprayer by moving the ON/OFF switch to the
OFF position.
Preparing to Paint
Before painting, it is important to make sure that the uid in the
system is compatible with the paint that is going to be used.
NOTE: Incompatibleuidsandpaintmaycausethe
valves to become stuck closed, which would
require disassembly and cleaning of the
sprayer’suidsection.
IMPORTANT: Always keep the trigger lock on the spray gun
in the locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
RAPID
CLEAN
2. Place the return hose into a metal
waste container.
3. Set the pressure to minimum by
turning the pressure control knob to
the “MIN” setting.
4. Move the PRIME/SPRAY valve down to the PRIME
position.
NOTE: Hold the return hose in the waste
container when moving the
PRIME/SPRAY valve to PRIME in
case the sprayer is pressurized.
5. Turn on the sprayer by moving the ON/OFF switch to the
ON position.
6. Allow the sprayer to run for 15–30 seconds to ush the
old solvent out through the return hose and into the metal
waste container.
7. Turn off the sprayer by moving the ON/OFF switch to the
OFF position.
NOTE: Make sure that the spray gun does not have a tip
or tip guard installed.
8. Move the PRIME/SPRAY valve up to the
SPRAY position.
9. Turn on the sprayer.
10. Unlock the gun by turning the gun trigger
lock to the unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
11. Trigger the gun into the metal waste container until the old
solvent is gone and fresh solvent is coming out of the gun.
Trigger lock in
locked position.
12. Lock the gun by turning the gun trigger
lock to the locked position.
13. Set down the gun and increase the
pressure by turning the pressure
control knob slowly clockwise.
14. Check the entire system for leaks. If
leaks occur, follow the “Pressure Relief
Procedure” in this manual before
tightening any ttings or hoses.
15. Follow the “Pressure Relief Procedure” in this manual
before changing from solvent to paint.
Be sure to follow the pressure relief procedure
when shutting down the sprayer for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
Painting
1. Place the siphon tube into a container of paint.
RAPID
CLEAN
2. Place the return hose into a metal
waste container.
3. Set the pressure to minimum by
turning the pressure control knob to
the “MIN” setting.
4. Move the PRIME/SPRAY valve down to
the PRIME position.
5. Turn on the sprayer by moving the ON/OFF
switch to the ON position.
6. Allow the sprayer to run until paint is
coming through the return hose into the metal waste
container.
7. Turn off the sprayer by moving the ON/OFF switch to the
OFF position.
8. Remove the return hose from the waste container and
place it in its operating position above the container of
paint.
9. Move the PRIME/SPRAY valve up to the
SPRAY position.
10. Turn on the sprayer.
11. Unlock the gun by turning the gun trigger
lock to the unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.