Product Manual

English
6 © Titan Tool Inc. All rights reserved.
12. Trigger the gun into the metal waste container until all air
and solvent is ushed from the spray hose and paint is
owing freely from the gun.
Trigger lock in
locked position.
13. Lock the gun by turning the gun trigger
lock to the locked position.
14. Turn off the sprayer.
15. Attach tip guard and tip to the gun
as instructed by the tip guard or tip
manuals.
POSSIBLE INJECTION HAZARD.
Do not spray without the tip guard in place. Never
trigger the gun unless the tip is in either the spray or
the unclog position. Always engage the gun trigger
lock before removing, replacing or cleaning tip.
16. Turn on the sprayer.
17. Increase the pressure by turning the pressure control
knob slowly clockwise and test the spray pattern on a
piece of cardboard. Adjust the pressure control knob until
the spray from the gun is completely atomized. Try to
keep the pressure control knob at the lowest setting that
maintains good atomization.
NOTE: Turning the pressure up higher than needed to
atomize the paint will cause premature tip wear
and additional overspray.
Control Panel Indicators
The following is a description of the control panel indicators.
RAPID
CLEAN
Pressure
Indicator
Motor
Running
Indicator
Pressure Indicator
The pressure indicator shows the current operating pressure of
the sprayer. It has three different indications: blinking yellow,
solid yellow, and solid green.
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 200 PSI. A blinking yellow pressure
indicator means:
The sprayer is plugged in and turned “ON”
The sprayer is at priming pressure (little or no pressure)
It is safe to move the PRIME/SPRAY valve between
positions
It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a
higher pressure and the PRIME/SPRAY valve
is in the SPRAY position, either the spray tip is
worn or the sprayer is in need of service/repair.
Solid Yellow
When the pressure indicator is solid yellow, the sprayer is
operating between 201 and 1900 PSI. A solid yellow pressure
indicator means:
The sprayer is at the proper pressure setting for spraying
stain, lacquer, varnish, and multi-colors
If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates
one of the following:
a. Tip Wear Indicator — when spraying with latex or at
high pressure the solid yellow appears. This means the
tip is worn and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the
sprayer is put in the gun, the pressure indicator will turn
from solid green to solid yellow.
c. Fluid Section Wear — if a solid yellow pressure
indicator appears when using a new tip and the pressure
is set at maximum, service may be required (worn
packings, worn piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is
operating between 1901 and 3300 PSI. A solid green pressure
indicator means:
The sprayer is at the proper pressure setting for spraying
oil-based and latex house paints
The sprayer is operating at peak performance at a high
pressure setting
Motor Running Indicator
The Motor Running indicator is on when the motor is commanded
to run. This indicator is used by service centers to troubleshoot
motor problems.
Digi-Trac™ Control System Operation
The Digi-Trac™ Control System is an optional add-on that
increases the functionality of the sprayer. It is installed directly
below the pressure control knob on the control panel. It consists
of a display and four function keys. The display shows various
menu screens that allow the user to customize and monitor
sprayer operation using the function keys.
SET PSI 3000
ACTUAL PSI 2950
Display
Function
Keys
Function Keys
The function keys are numbered 1–4. Each key is labeled with
an additional function as well.
#1/Menu Key
Pressing the #1 key scrolls through the available menu screens
or performs a function described on the active menu screen.
#2/+ Key
Pressing the #2 key performs a function described on the active
menu screen or increases a value.
#3/- Key
Pressing the #3 key performs a function described on the active
menu screen or decrease a value.
#4/Select Key
Pressing the #4 key selects the active menu screen or performs
a function described on the active menu screen.
Menu Screens
Several menu screens are available for the user to customize
and monitor sprayer operation. They include Main Screen, User
Pre-Sets, Volume Pumped, Job Volume, Unit Serial #, TImers,
Job Timers, Service Time, Security Code, Prime, and RAPID
CLEAN.