811 Advantage Product Data Sheet

PHYSICAL PROPERTIES
• Type: Urethane • Calculated VOC: 28 g/L
• Color: Brown • Weight/gallon: 12.4 lbs.
• Solids: 95% • Viscosity: 100,000 cps
• Flashpoint: >200˚F (Pensky-Martens Closed Cup)
• Freeze/Thaw stability: Not affected by freezing
• Storage life: 1 year in tightly closed container
SUBFLOOR PREPARATION
All substrates must be clean, dry, structurally sound, properly cured and free of dirt, oil, paint,
old adhesive, wax, sealers and curing agents. General scouring with 20 grit or #3 1/2 open-coat
sandpaper will remove most compounds. All loose materials must be vacuumed from the surface
after scouring. The subfloor must be flat to a tolerance of 3/16” in a 10’ radius. Hollow spots,
popping spots and squeaks are related to unevenness in the subfloor. Grinding concrete floors is
preferred over the use of filling compounds. If filling/flattening compounds are used, they must
be Portlandbased cementitious material and have a compressive strength equal to or greater than
3000 psi when cured. Use of adhesive over light weight concrete and all gypsum-based materials
requires the use of Titebond Concrete Primer or an approved concrete primer prior to application
of adhesive. Remove all existing base, shoe molding and door thresholds prior to continuing the
installation. All door casings must be undercut with either a jamb saw or a hand saw. Use a piece
of the flooring as a guide to determine the thickness needed.
INSTALLATION
Titebond 811 Advantage can be installed using the “wet lay” or “flashed” methods, depending
on your preference and the environment of your installation. In the “wet lay” method you do
not flash the adhesive. Once the adhesive has been troweled, the wood flooring may be installed
immediately into the wet adhesive. To reduce slippage, secure the first starter row with Titebond
Tape. Remaining planks must be placed firmly into adhesive. Planks which are not flat should be
weighted for several hours. In the wet lay method, you should not work on top of the wood. The
“flashed”* method is when the adhesive is allowed to flash for the recommended amount of time
prior to installing the wood flooring. While using this method, you are advised to trowel out larger
sections of the room so that you spend most of your time laying wood rather than flashing
adhesive. Be careful not to exceed 811 Advantage’s open time of 90 minutes and do not trowel
more adhesive than you can comfortably cover with the flooring in 90 minutes.
* The recommended flash time for Titebond 811 Advantage is 30 minutes, depending upon
subfloor moisture and humidity.
Titebond 811 Advantage may be used for above-, on- and below-grade applications and on
all substrates listed in this specification guide. All applications are susceptible to moisture and
should be tested for moisture prior to installation in several locations within the installation
area. Acceptable conditions of concrete for above-, on- and below-grade applications are:
Less than 3 lbs. /1000 sq.ft./24 hours on a Calcium Chloride Test (ASTM F1869)
Less than a reading of 4.5 on a Tramex Concrete Moisture Encounter
Relative humidity (RH) of 75% or less when tested with an in situ probe (ASTM F2170)
Acceptable conditions of wood substrates are a moisture reading of less than 12% or be no
more than 4% different from the flooring being installed when using a Tramex, Delmhorst or
equivalent wood moisture meter. If subfloor moisture conditions do not meet above guidelines
at the time of flooring installation, or they could exceed them at any time after installation,
then a Titebond moisture control system should be used.
APPLICATION GUIDELINES
TYPE OF FLOORING/FLOORING THICKNESS TROWEL SIZE COVERAGE
All parquets measuring less than 3/4” in thickness ......................................................................................................... 1/8” x 1/8” x 1/8” (Square-notch) ...................................... 65 sq. ft. per gallon
All engineered flooring ....................................................................................................................................................3/16” x 1/4” x 1/2” c-c (or 5/16” space) V-notch ............... 50 sq. ft. per gallon
Solid flooring and bamboo with a width less than 3” & measuring 5/8” or less in thickness .........................................3/16” x 1/4” x 1/2” c-c (or 5/16” space) V-notch ............... 50 sq. ft. per gallon
Solid flooring and bamboo with a width greater than 3” & measuring 5/8” or less in thickness, & 3/4” shorts ...........3/16” x 3/16” x 3/16” (Square-notch) ............................... 35 sq. ft. per gallon
Cork underlayment ...........................................................................................................................................................1/16” x 1/16” x 1/16” (Square-notch) ................... 125 to 185 sq. ft. per gallon
V-notchSquare-notch
by
VISIT WWW.TITEBOND.COM FOR THE
MOST UP-TO-DATE PRODUCT INFORMATION
Type of Flooring/Flooring Thickness: All parquets measuring less than 3/4” thick / All engineered flooring / Solid wood flooring measuring 5/8” or less in thickness / Bamboo flooring /
3/4” solid shorts (less than 24”) / 5/8” plywood (2’ x 8’ or 4’ x 4’)
Jobsite/Subfloor: New, old or existing concrete, properly treated light weight concrete / Below-grade concrete / Plywood / OSB (oriented strand board) / Radiant heated slabs /
Clean and unwaxed vinyl/cork
CLEAN UP
As the pre-finished flooring is being installed, immediately wipe any wet adhesive from the flooring, tools and equipment with mineral spirits or Titebond Adhesive Remover Cleaning Wipes.
Do not allow adhesive to cure on surface of the flooring, tools or equipment. Follow solvent manufacturer’s directions when working with solvents. For specific cleaning instructions, call Franklin
Technical Service at 1.800.347.4583.
DANGER. Harmful if inhaled. Causes skin and eye irritation. May cause allergic skin reaction. May cause allergy or asthma symptoms, or breathing difficulties if inhaled.
May cause respiratory irritation. May cause damage to organs (lungs) through prolonged or repeated exposure if inhaled. Wear protective gloves, and eye or face protection.
In case of inadequate ventilation wear respiratory protection. Use only outdoors or in a well-ventilated area. Do not breathe vapor. Wash hands thoroughly after handling.
FIRST AID: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or physician if you feel unwell. IF
EXPERIENCING RESPIRATORY SYMPTOMS: Call a POISON CENTER or physician. IF ON SKIN: Wash with plenty of soap and water. Wash contaminated clothing before reuse.
IF SKIN IRRITATION OR RASH OCCURS: Get medical attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove any contact lenses and continue rinsing.
IF EYE IRRITATION PERSISTS: Get medical attention. Dispose of contents and container in accordance with all local, regional, national and international regulations.
For additional information, refer to Safety Data Sheet.
IMPORTANT NOTICE: Our recommendations, if any, for the use of this product are based on tests believed to be reliable. Furthermore, nothing contained herein shall be construed as a
recommendation to use any product in conflict with existing laws and/or patents covering any material or use.
WARRANTY: The full warranty for Titebond 811 Advantage and all Titebond flooring products can be obtained at www.Titebond.com or by calling 1.800.347.4583.
Columbus, Ohio 43207 614.443.0241 (Technical Service 1.800.347.4583) © 2017 BCM2803 8/17 FF946