User's Manual

4-18
Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER)
7. SERIAL BRIDGE SETTING
NX-100 only
Perform serial bridge settings.
(1) Enable/Disable Selection
Select "Enable" when using this function. All items can be ready for entry.
(2) Network Setting
[Protocol]
Select the serial bridge communication configuration.
TCP Server: The original unit carries out communications as a TCP server. The NX-100 unit connected to
this server must be set as a TCP client in its protocol settings.
TCP Client: The original unit carries out communications as a TCP client. The target NX-100 unit must
be set as a TCP server in its protocol settings.
UDP: Carries out communications using UDP. The target NX-100 unit's protocol settings must be
set to UDP.
[Target Unit's IP Address]
Enter the target unit's IP address and port number.
Note
Enter the global IP address if using the Internet.