user manual

– 53 –
No.
12
Item
Louver control
(Continued)
Outline of specifications
<<Selection of Swing mode>>
For the Swing mode, the following three types of modes are
selectable and settable by keeping Swing/Direction
SWING/FIX
button pushed for 4 seconds or more on the remote controller.
Standard (4 pieces: same phase) swing
Data: [0001 (At shipment)]
When Swing operation is selected, four louvers align at the
horizontal discharge position and then start the Swing
operation at the same time.
Dual swing Data: [0002]
When operation is selected, the louvers of louver No. [01]
and [03] move to the horizontal discharge position, the
louvers of louver No. [02] and [04] move to the downward
discharge position and then start the Swing operation at the
same time.
Cycle swing Data: [0003]
When operation is selected, the louver No. [01] moves to the
horizontal discharge position, [03] to the downward dis-
charge position, [02] and [04] to the middle position and
then start the Swing operation at the same time.
Three types of the swing modes can be also selected and set
by the setup data of Item code (DN) [F0].
In case of selecting the Swing mode, “Dual swing” or “Cycle
swing”, the following numerals is displayed at the center of the
remote controller screen for approx. 3 seconds when
SWING/FIX
button was pushed to select [SWING].
(No display for the standard swing)
Remarks
On the remote control-
ler before the wired
remote controller
(RBC-AMT31E), the
mode cannot be moved
to the select mode
even if pushing
SWING/FIX
button for a long time.
Carry out setting
operation during stop of
the unit; otherwise the
unit stops operation.
The standard swing
performs the same
swing operation as the
present operation
(2 series).
For the setting opera-
tion, refer to [How to
set up type of the
swings] in Item “Setup
at local site/Others”.
On the remote control-
ler before the wired
remote controller
(RBC-AMT31E),
flashing showing the
Swing mode is not
indicated.
<<Louver lock (Louver fix)>>
For the air direction setup for each discharge port, the louver
position can be locked during the normal operation.
An arbitrary air direction of an arbitrary louver can be
registered and set by keeping
UNIT LOUVER
button pushed for
4 seconds or more on the remote controller.
The louver lock can be set by registering the setup data to Item
code (DN) [F1] to [F4] according to the following table.
Item code
F1
F2
F3
F4
Objective louver No.
01
02
03
04
Setup data
0000: Release (At shipment)
0001: Horizontal discharge position
~
0005: Downward discharge position
Alternate lighting
(0.5 sec.)
Alternate lighting
(0.5 sec.)
Dual swing
Cycle swing
On the remote control-
ler before the wired
remote controller
(RBC-AMT31E),
UNIT LOUVER
button is not
provided.
Carry out setting
operation during stop
of the unit; otherwise
the unit stops opera-