2.15 Tablet Pen Troubleshooting 2 Troubleshooting Procedures
2-52 Satellite R10 Maintenance Manual (960-509)
Procedure 3 Connector/Replacement Check
The Digitizer and LCD are connected to the system board as below.
Check 1 The Digitizer might be disconnected. Make sure the Digitizer is connected to the
CN9540 on the system board. If there is still an error, go to Check 2.
Check 2 The LCD might be disconnected. Make sure the LCD is connected to the CN5501
on the system board. If there is still an error, go to Check 3.
Check 3 The Digitizer, the LCD or the system board might be defective. Replace it with a
new one following the steps in Chapter 4. Then check the tablet pen is working
properly.