Turn the on the controller to on and wait until the water draining
operation ends.
Remove the Supplementary Protector cover and turn the power lever to
off.
Please operate with the On/Off button set to off.
After around two minutes, the water draining operation will end.
Please keep from scratching or letting debris to get on the packing. Otherwise, leaks could develop or
debris could get inside the function module and cause problems.
Please attach the water drain plug without a filter to the connection port on the far left.
After removing the water, reattach the water drain plugs to the three
places where they were.
Turn off the circuit breaker.
Please open the inspection door for the shower, which is located near the shower (built on site) and turn
off the water shut-off valves.
Please follow the procedure in “Before using it for the first time” (See page 13) when you want to use it
again.
Water drain plug
Water drain plug
(with filter)
Packing
Packing
Filter
Packing
Supplementary
Protector cover
Power lever
ON
OFF
Reattach the Supplementary Protector cover as it was.