Item Brochure

65
B
A
C
ICP Control Panels
Housing & Construction:
.040 Gold anodized Aluminum housing for efficient, long-term
reflectivity and corrosion resistance. High-density radiant heat.
Housing is ETL Listed for indoor, dry environment applications
only. Made in U.S.A.
Reflector:
60 degree symmetric heat pattern, reference the sizing chart to
determine overall coverage based on the mounting height.
Elements:
Heavy duty flat panel emitter. Available wattages in 1450, 3150,
4300 and 9500 Watts per element. Available in standard voltages
from 120 to 600 Volts.
Controls:
Flat panel emitter heaters are not manufactured with any control
device on the unit. All controls and accessories should be
specified as remote mounted. Please consult the technical sales
department of factory for help in determining applicable controls.
Please follow installation instructions that accompany each
heater.
Accessories:
Power contactor panels.
FSS-95
Product Specications
Mounting Clearances & Recommended Mounting Height
FSS Series Dimensions
Sizing Chart
Mounting Clearances KW Recommended Mounting Height
All FSS Models
24” from ceiling
36” from vertical surface & from another heater
72” from face of heater to combustible surface
1.4 8’ - 10’
3.1 8’ - 12’
4.3 10’ - 14’
9.5 12’ - 16’
FSS-95 Tandem Only 87” from face of heater to combustible surface (2) 9.5 15’ - 30’
FSS Series Heavy Duty Flat Panel Emitter Electric Overhead Infrared Heater
(2)
FSS-95 heaters with TMK-95 tandem mounting kit
MOUNTING
HEIGHT
MFG
MODEL
NUMBER
LENGTH WIDTH
COVERAGE
(SQ. FT.)
WATTS
(SQ. FT.)
8’
FSS-14 8 8 64 22.7
FSS-31 9 8 72 43.8
10’
FSS-14 11 10 110 13.2
FSS-31 11 10 110 28.6
FSS-43 12 10 120 35.8
12’
FSS-31 12 11.5 138 22.8
FSS-43 14 12 168 25.6
FSS-95 15 13 195 48.7
14’
FSS-43 16 14 224 19.2
FSS-95 18 16 288 33.0
16’
FSS-43 18 16 288 14.9
FSS-95 21 18 378 25.1
FSS-95
TANDEM
24 19 456 41.7
18’
FSS-95 23 20 460 20.7
FSS-95
TANDEM
28 20 560 33.9
20’
FSS-95
TANDEM
28 23 644 29.5
24’
FSS-95
TANDEM
33 27 891 21.3
30’
FSS-95
TANDEM
41 32 1312 14.5
NEMA 4 outdoor rated control box
Door interlock disconnect switch
• Custom made to customers specications
• SCR and proportional controls optional
• Circuit reakers sized for heater load per stage
Please see ICP page to select panel to
control one or multiple units, if required.
Features
MFG
MODEL
NUMBER
DIMENSIONS (in.)
“A”
DEPTH
“B”
WIDTH
“C”
LENGTH
FSS-14 8
1
2 9 26
FSS-31 8
1
2 9 46
FSS-43 9
3
4 20 29
FSS-95 7
3
4 20 49
FSS-95 TANDEM 7
3
4 20 108
3/4” K.O. ON FSS-43,-95
1/2” K.O. ON FSS-14, -31